Technical Parameters |
|
Compliant With Standards |
VW 80300:2021、 QMAT 5502-2023、Q/JLY JT111974A-2024 |
Test Voltage Vmax |
1500 V |
Test Current Imax |
100 A |
Capacitance |
10 uF – 1200 uF(accuracy 2%, step 10 uF) |
Internal Resistance |
0 Ω – 6 Ω(accuracy 2%, step 0.05 Ω) |
Discharge Resistance |
50 Ω – 1200 Ω(accuracy 2%, step 10 Ω) |
High Voltage Ves |
80% – 99%(step 1%) |
Maintain Time Th |
1 s – 9999 s(step 1 s) |
End Voltage Vend |
5 V – 20 V(step 1 V) |
General Parameters |
|
Display |
5.7-inch TFT touch screen |
Scope of Working Power Supply |
AC 220V±10%,50/60Hz±5% |
Fuse |
6A |
Maximum Power Consumption |
200 W |
Communication Method |
Ethernet LAN |
Pulse Triggering Method |
Automatic |
Safety Circuit |
Press emergency stop, the instrument stops working |
Failure Detection |
When it fails, the front panel LCD displays and interrupts the instrument's operation |
Instrument Working Status Indication |
Front panel LED indication, LCD display |
Instrument Grounding Connection Method |
Use a flat grounding wire |
Chassis Size |
22U L * W * H: 1250 * 800 * 600 mm |
Instrument Weight |
About 185 kg |
temperature Range |
15 – 35℃ |
Humidity Range |
45% - 75% |
Compressed Air |
86 kPa - 106 kPa |
Standard Accessories:
Power Cord, Fuse, Test Wire, Grounding Wire, Instruction Manual