Technical Parameter |
|
Test Current Range |
20 A ~ 6000 A(±10% ±1 A) |
Current Wavefront Time |
8 μs ± 10%, wavefront time definition: 1.25 * (10%~90%) |
Half Peak Time of Current |
20 μs ± 10%, definition of half peak time: 1.18 * (50%~50%) |
Equivalent Output Impedance |
≤14.5 Ω(20 A≤I<200 A) |
Output Polarity |
Positive, negative, first positive and then negative |
Test Interval |
5 s~180 s (the shortest time depends on the test voltage) |
Test Frequency |
1 ~ 10000 |
Pulse Triggering Method |
Manual, automatic, externally triggered |
General Parameters |
|
Display |
5.7-inch TFT touch screen |
Scope of Working Power Supply |
AC 220 V, ± 10%, 50 Hz ± 5% |
Fuse |
6A |
Maximum Power Consumption |
300 W |
Communication Method |
Ethernet LAN |
External Trigger Input |
BNC, 5V TTL |
CRO Triggers Output |
BNC, 5V TTL |
Operation Control Input |
BNC, 5V TTL |
Instrument Grounding Connection Method |
Use a flat grounding wire |
Chassis Size |
6U L * W * H: 620 * 450 * 280 mm |
Instrument Weight |
About 29 kg |
Environmental Scope |
15 ℃ ~ 35℃ |
Pressure Range |
86 kPa ~ 106 kPa |
Humidity Range |
45% ~ 75% |
Standard Accessories |
|
Test Line, Power Line, Grounding Wire, Fuse (spare parts), Instruction Manual, Factory Report. |
|
Optional Accessories |
|
CPN 2216S current wave coupling decoupling network |
The maximum coupled pulse current can reach 6 kA. EUT maximum load capacity AC 220 V 16 A single-phase DC 220 V 16 A |
Tel: +86 (0)512 6807 7192