Introduction:
The conducted interference sensitivity testing system CST 10500D (50M) is designed according to ISO 7637-4 and is used for RF induced conducted immunity testing with frequencies ranging from 100 kHz to 50 MHz. The testing equipment consists of a signal generator, a broadband power amplifier (Class A), and a power meter with high dynamic range integrated into one device. All testing equipment is controlled by PC software and has functions such as saving test results.
Features:
> Integrated design, built-in signal generator and power meter;
> Remote control through PC software;
> Compliant with ISO 7637-4 standard.
|
Technical Parameters |
|
|
RF Signal Generator |
|
|
Frequency Range |
1 μHz~ 50 MHz |
|
Frequency Resolution |
1 μHz |
|
Frequency Temperature Stability |
±1 ppm+10 pHz |
|
Harmonic |
<-55 dBc |
|
Non Harmonic |
<-60 dBc |
|
Output Power Range |
≤10 MHz:1.0 mVpp~10 Vpp |
|
≤30 MHz:1.0 mVpp~5.0 Vpp |
|
|
≤50 MHz:1.0 mVpp~2.5 Vpp |
|
|
Power Accuracy |
±1.0 dB |
|
Resolving Power |
0.1 dB |
|
Internal Modulation Source (LF) |
Sine wave 2 mHz~1 MHz; |
|
Square wave 2 mHz~1 MHz; |
|
|
Triple wave/saw wave 2 mHz~1 MHz |
|
|
Amplitude Modulation (AM) |
Modulation depth 0%~120%; |
|
Frequency Modulation (FM) |
Maximum frequency offset: 5 MHz |
|
Phase Modulation (Ø M) |
Modulation phase 0 °~360 °; |
|
Pulse Cycle |
1 μs to 500 s |
|
Pulse Width |
0 ns~100 s |
|
Output Interface |
N (Mother) |
|
VSWR |
<1.5:1 |
|
Power Amplifier |
|
|
Frequency Range |
100 kHz ~ 50 MHz |
|
Gain |
58.5 dB±1 dB (500 W) |
|
1 dB Gain |
57 dB±1 dB (500 W) |
|
VSWR |
<1.5:1 |
|
Output Impedance |
50 Ω |
|
Output Interface |
N (Mother) |
|
Power Meter |
|
|
Frequency Range |
9 kHz ~ 6 GHz |
|
Test Voltage Level |
-50 dBm ~ +20 dBm |
|
Accuracy |
±0. 2 dB |
|
Input Interface |
N (Mother) |
|
VSWR |
<1.1:1 |
|
General parameters |
|
|
Scope of Working Power Supply |
AC 110 V/220 V ±10%,50 Hz /60 Hz±5% (Default AC 220 V 50 Hz in mainland China) |
|
Maximum Power Consumption |
500 W |
|
Size |
22U cabinet L * W * H: 1250 * 800 * 600 mm |
|
Weight |
About 60 kg |
|
Ambient Temperature |
15 ℃~35 ℃ |
|
Relative Humidity |
45%~75% |
|
Atmospheric Pressure |
86 kPa~106 kPa |
|
Standard Accessories |
|
|
Attenuator, Power Cord, USB Cable, Flat Grounding Wire, Factory Report, RF Cable, Fuse, Instruction Manual. |
|
|
ISO 7637-4A Wave Test Item Equipment Accessories |
|
|
Attenuator |
40 dB/200 W frequency range DC~1 GHz |
|
Balanced/Unbalanced |
TBT-500: 500 V; 100 kHz ~ 50 MHz; |
|
High Voltage Artificial Network |
TANHV 200:100 kHz ~ 150
MHz; 200 A; |
|
50 Ω Load |
50 Ω/80W frequency range DC~1 GHz |
|
High Voltage Shielding Cover |
HVSE 400 |
|
High Voltage Battery Load |
7637-4R500/120 3000 W |
|
Testing Software |
EMC-S 7637-4 |
|
Test environment |
|
|
Conducted indoors without shielding |
Test table:2,400 mm *1,000 mm *900 mm |
|
Grounding reference board:2,400 mm *1,000 mm *1,200 mm |
|