The INR 60 Inductive Noise Immunity Tester is developed according to the Toyota TSC0502G Fig.22 standard. It simulates the high-voltage noise waveform generated in a vehicle and can be connected to a remote PC via Ethernet to print a test report.
> 5.7-inch color touch screen front panel operation;
> Built in standard waveform, convenient and fast;
> Ethernet and RJ45 interfaces, used for PC remote control and printing test reports;
> PC control software AutoLab is optional;
> The indicator light displays frequency selection for easy differentiation.
General Parameters |
|
Display |
5.7-inch TFT touch screen |
Scope of Working Power Supply |
AC 110 V/220 V,±10%, 50/60 Hz (default AC 220V in China) |
Fuse |
6 A |
Maximum Power Consumption |
300 W |
Communication Method |
Ethernet |
External Trigger Input |
BNC, 5V TTL |
CRO Triggers Output |
BNC, 5V TTL |
Operation Control Input |
BNC, 5V TTL |
Pulse Triggering Method |
Manual, automatic, externally triggered |
Instrument Grounding Connection Method |
Use a flat grounding wire |
Chassis Size |
6U L * W * H: 550 * 450 * 280 mm |
Instrument Weight |
About 22 kg |
Environmental Scope |
15℃~ 35℃ |
Pressure Range |
86 kPa ~ 106 kPa |
Humidity Range |
45% ~ 75% |
Technical Parameters |
|
Test Voltage Range |
0.1 MHz、5 MHz、10 MHz :100 V - 600 V (0%-10%) 100 MHz:100 V - 500 V (0%-10%) 30 MHz:100 V - 600 V (0%-10%)注:200 V(0%-5%) |
Pulse Waveform |
Damped oscillatory wave |
Pulse Oscillation Frequency |
0.1、5、10、30 MHz:±10%;100MHz:±25% |
Pulse Rise Time(10%-90%) |
≤50 ns @0.1 MHz;≤10 ns @5、10、30MHz、100MHz; Vp5/Vp1≥30%@0.1、5、10、30 MHz; Vp3/Vp1≥30%@100 MHz
|
Attenuation Ratio |
Resistive load: 1000 Ω or greater |
Source Output Impedance |
50 Ω |
Output Polarity |
Positive |
Pulse Cycle |
100 ms@0.1 MHz;10 ms@5、10、30、100 MHz |
Duration |
1-999 s |
Test Interval Time |
1-9999 s |
Test Frequency |
1-9999 |
Trigger Method |
Automatic, manual, external triggering |
Output Terminal Form |
MC insulated terminal (coaxial 1000:1 attenuator with input impedance of 1000 Ω for 100 MHz, bandwidth of 400 MHz and above); Differential probes with a bandwidth of 200 MHz or higher are used for other frequencies; Calibration requires the use of an oscilloscope with a bandwidth of 400 MHz or higher |
Standard Accessories |
Test wires, Power lines, Grounding Wires, Fuses (spare parts), Instructions, and Factory Reports. |
Optional Accessories |
PC control software AutoLab Supporting Windows 7/Windows 8/Windows 10/Windows 11, it is easy to use, with a beautiful and intuitive user interface. Various operational functions and standard testing libraries enable users to easily complete custom testing programs; Users can customize any waveform (outside of the standard library); It can automatically/manually identify the connected AutoLab testing equipment and perform automatic configuration; The template based reporting feature can help users generate test reports flexibly. |