CCS 1000 is an intelligent multifunctional compact immunity (EMS) test system, which meets all the requirements of international standards and product standards for transient pulse, surge and voltage dip. Its test voltage is up to 10 kV. CCS series are the best choice for full compliance immunity test solutions. It not only meets the immunity testing requirements of CE, but also be capable of performing three-phase-five-line EUTs tests by using automatically controlled external CDNs (up to 400 A) of our company. Various enclosures needed are available to satisfying types of needs such as power frequency magnetic field tests.
Features:
> 5.7” color touch screen
> EUT surge failure detection function
> Ultra small simulator with a maximum capacity of 10.0 KV
> Surge test voltage and current monitoring and measurement
> Test the scheduling function
> Optional for external three-phase CDN modules
> Ethernet (RJ45 interface), used for PC remote control and printing test reports.
General Parameters |
|||
Display Screen |
5.7” TFT color touch screen |
Power Supply |
AC 110 V/220 V(士10%),50 Hz /60 Hz(±5%)(default AC 220 V 50 Hz in mainland China) |
Fuse |
6 A |
Max Power Consumption |
200 W |
Memory Space |
Infinite (PC storage) |
Communication Mode |
Ethernet (RJ45) |
Dimension |
19”/6U |
Weight |
Approx.32 kg |
Ambient Temperature |
15℃~35℃ |
Relative Humidity |
45%~75% |
Atmospheric Pressure |
86 kPa~106 kPa |
|
|
EFT/burst Tests as per IEC 61000-4-4 |
|||
Test Voltage |
0.25 kV~5 kV(±10%) |
Burst Duration |
0.075 ms~750 ms |
Source Impedance |
50 Ω |
Burst Cycle |
11 ms~9999 ms |
Rise Time |
5 ns(±30%),50 Ω load, 1000 Ω load |
Polarity |
Positive, negative, alternative |
Pulse Duration |
50 ns±30%,50 Ω load |
Test Duration |
1 s~9999 s |
50 ns-15/+100 ns,1000 Ω load |
Phase synchronization |
0° ~360°,1° step or random |
|
Pulse Frequency |
0.1 kHz-1000 kHz |
Trigger Mode |
Automatic, manual or external trigger |
Surge Tests as per IEC61000-4-5 |
|||
Test Voltage |
0.3 kV~10 kV(±10%) |
Polarity |
Positive, negative, alternative |
Test Current |
0.15 kA~5 kA(±10%) |
Trigger Mode |
Automatic, manual or external trigger |
Voltage Waveform |
Front time: 1.2 μs (±30%), Time to half value: 50 μs (±20%) |
Pulse period |
8 s~99 s (the shortest depends on test voltage) |
Current Waveform |
Front time: 8 μs (±20%), Time to half value:20 μs (±20%) |
Number of Test |
1~999 |
Source Output Impedance |
2 Ω |
Phase synchronization |
0° ~360°, 1° step or random |
Coupling Resistance |
10 Ω, 0 Ω coupling resistor Either IEC standard mode or customized mode is optional 3 digits on display |
Surge Voltage andCurrent Peak Detection |
Front panel BNC output, surge voltage: 1000 V:1 V Surge current: 500 A:1 V |
Coupling Capacitance |
9 μF, 18 μF |
|
|
PFMF Tests as per IEC61000-4-8 with optional module MFT 400/1200 or VMT series and magnetic field coils |
|||
Continuous Operating Current Range |
1 A~120 A |
Test Duration |
1 s~28800 s |
Current Waveform |
50 Hz/60 Hz sine wave |
Waveform Interval |
1 s~9999 s |
Current Distortion Rate |
<5% |
Coil Size |
1000mm*1000mm (TCXS111/TCXS113) |
Operating Current Range for Short Time |
120 A~500 A |
Coil shape |
Rectangle |
Magnetic Field Strength |
TCXS 111 Single-turn coil: 1 A/m ~100 A/m (continuous) 100 A/m ~400 A/m (1 s-10s in short time) TCXS 113 Three-turn coil: 1 A/m ~300 A/m (continuous) 300 A/m ~1200 A/m (1 s-10 sin short time) |
Trigger mode |
Auto, Manual, External signal trigger |
Magnetic Field Output Accuracy |
Deviation 1dB(minimal magnetic field intensity like 1A/m needs to be adjusted manually before tests.) |
Output Magnetic Field Strength |
Test Sequencing setup |
Pulse Magnetic Field Tests as per IEC 61000-4-9 with optional module PMC 1200 and magnetic field coils |
|||
Output Magnetic Field Range |
100 A/m~1200 A/m |
Model of Coil |
TCXS 111 |
Output Current |
100 A~2000 A |
Coil Size |
1000*1000mm |
Waveform |
Risetime: 7.2μs~10.4μs duration: 18μs ~26μs |
Coil Shape |
Rectangle |
Polarity |
Positive,negative, alternative |
Coil Turn |
Single |
Pulse Cycle |
5 s~99 s(the shortest depends on test current) |
Trigger Mode |
Automatic, manual or external trigger |
Phase synchronization |
0°~360°, 1° step or random |
Output Magnetic Field Strength |
Test sequencing setup |
Number of Test |
1~999 |
|
|
Power Fail Tests as per IEC 61000-4–11 (with Optional Module VVT or VMT series) & IEC 61000-4-29 |
|||
EUT Max. Voltage |
300 V AC, 300 V DC |
Voltage Variation Level |
0~100% |
EUT Max. Current |
AC/DC 16 A continuous current; AC 20 A continuous 5 s; 40 A continuous 3 s; 500 A impulse current |
Time of Voltage Variation Decreasing |
500 ms~9999 ms (50%~100%) or abrupt (same with rise/ fall time for dips and interruption) 1000 ms~9999 ms (0%~100%) or abrupt (same with rise/ fall time for dips and interruption) |
Dip Level |
0%~100%(for VVT/VMT series) 0%,40%,70%,80%(for VVTxxxxSFseries) |
Duration after Voltage Variation Decreasing |
10 ms-99999 ms |
Interruption level |
0% |
Time of Voltage Variation Increasing |
500 ms~9999 ms(50%~100%) 1000 ms~9999 ms(0%~100%) |
Dip and Interruption Rise/Fall Time |
1 µs ~5 µs (100Ω load) |
Phase synchronization |
0°~360°, 1° step or random |
Dip and Interruption Interval |
5 ms~9999 ms |
Trigger Mode |
Automatic, manual or external trigger |
Dip and Interruption Duration |
0.1~9999 cycle or 1ms~9999ms |
EUT Current and Voltage Measurement |
LCD display, BNC terminal: voltage 100:1, current 10 A:1 V |
Dip and Interruption Test Duration |
1 s~9999 s |
|
|
Models Selection |
||||||||
Name |
Model |
IEC 61000-4-4 |
IEC 61000-4-5 |
IEC 61000-4-8 |
IEC 61000-4-9 |
IEC 61000-4-11 |
IEC 61000-4-29 |
CDN single- phase-3-line |
Compact Immunity Test System |
CCS 1000 |
√ |
√ |
√ |
√ |
√ |
√ |
|
EFT/Burst CDN |
EFTN 3816T |
√ |
|
|
|
|
|
|
Surge CDN |
SPN 3816T |
|
√ |
|
|
|
|
|
EFT/Burst and Surge CDN |
SEPN 3816T |
√ |
√ |
|
|
|
|
|
SEPN 3832T |
√ |
√ |
|
|
|
|
||
Power Frequency Magnetic Module |
MFT 400 |
|
|
√ |
|
|
|
|
MFT 1200 |
|
|
√ |
|
|
|
||
AC Voltage Dips, Short Interruption and Variation Module |
VVT 2216S |
|
|
|
|
√ |
|
|
VVT 2216SV |
|
|
|
|
√ |
|
||
Power Fail and Power Frequency Magnetic Module |
VMT 2216S |
|
|
√ |
|
√ |
|
|
VMT 2216SV |
|
|
√ |
|
√ |
|
||
Pulsed Magnetic Field Converter |
PMC 1200 |
|
|
|
√ |
|
|
|
Coil |
TCXS111 |
|
|
√ |
√ |
|
|
|
TCXS113 |
|
|
√ |
|
|
|
Accessories |
User Manual, Fuse×2(spare parts), Flat Grounding Wire, Radio-Frequency Wire, Testing Wire, Power Supply Wire |
* CCS 1000 does not include built-in single-phase network and can be equipped with external coupling decoupling network for single/three-phase.