CWS 2000C&CWS 2000T communication surge immunity tester is a high testing equipment specially designed to simulate surge pulse interference. CWS 2000T can generate high voltage pulse waveforms of 10/700μs and 5/320μs, meeting the requirements of IEC 61000-4-5 and other standards.
The performance of CWS 2000C &CWS 2000T fully meets the requirements of EU CE certification and CCC certification for the immunity test of the tested equipment.
Features:
> 5.7-inch colorful touch screen;
> Voltage can reach 20 kV;
> As per IEC 61000-4-5 and GB/T 17626.5;
> Display peak voltage / current on LCD;
> Test sequencing and scheduling, easy test setting;
Instrument introduction | |
CWS 2000C |
Communication surge immunity tester control |
CWS 2000T |
10/700μs&5/320μs communication surge generator |
Technical Parameters | |
Test Voltage Range |
0.5 kV ~ 20 kV ±10% |
Voltage Waveform |
Front time: 10μs ±30%; Pulse width: 700μs ±20% |
Test Current Range |
12.5 A ~ 500 A ±10%(40 ohm) |
Current Waveform |
Front time: 5μs ±20%; Pulse width: 320μs ±20% |
Source Impedance |
15 ohm, and 40 ohm to select |
Output Polarity |
+, -, +/- |
Pulse Period |
11 s ~ 180 s (the min. depends on the test voltage) |
No. Of Tests |
1 ~ 999 |
Peak voltage monitor |
BNC output : 2000 V:1 V; LCD display |
Peak current monitor |
BNC output : 100 A:1 V; LCD display |
Triggering Method |
Automatic / manual / external triggering |
Test mode |
Test parameter scheduling setting |
General Parameters | |
Display |
5.7-inch colorful touch screen |
Operating Power Supply |
AC 110 V / 220 V±10%, 50 Hz / 60 Hz (AC 220 V in China) |
Fuse |
6 A |
Max Power |
1000 W |
User storage space |
Infinite(PC) |
Communication Method |
Ethernet and RJ 45 |
Operating State Indicators |
Front panel LED, LCD |
Malfunction Detection |
Malfunctions will be shown on LCD while the operation will be stopped. |
Monitor output way |
1 meter coaxial-line |
Dimension |
35 U |
Weight |
Approx. 108 kg |
Operating Temp. |
15℃ ~ 35℃ |
Operating Humidity |
45% ~ 75% |
Operating Air Pressure |
86kPa ~ 106kPa |
Standard Accessories |
Power line, Test lines, Ground line, User manual , Coaxial-line, Fuses, CN 25, Factory report |
Optional Accessories |
1. Signal/Communication lines coupling/decoupling network: IEC 61000-4-5 CDN 405 series |
2. Broadband current monitoring pliers : CM 0220M Attenuation : 0.01 V/A; |
3. PC software: Corelab With PC installed WIN 7, WIN 8 and WIN 10, it can be easily operated to make the measurement, based on the customized test program. It can identify any device with automatic configuration. It can easily generate test reports. |