CWS 800CT combination wave lightning surge simulator is a high-end test equipment specially designed for simulating surge pulse interference, which can generate high-voltage pulse waveforms of 1.2/50μs, 8/20μs, 10/700μs and 5/320μs. Meet the requirements of IEC 61000-4-5 and other standards.
The performance of CWS 800CT fully meets the requirements of EU CE certification and CCC certification for the immunity test of the equipment under test, and the surge test can be carried out on the equipment under test through an external coupling/decoupling network.
Features:
> 5.7-inch colorful touch screen;
> Voltage can reach 8 kV;
> Generate 1.2/50μs, 8/20μs, 10/700μs, 5/320μs high voltage pulse waveforms; As per IEC 61000-4-5;
> Display peak voltage / current on LCD;
> Test sequencing and scheduling, easy test setting;
> Equipped External three-phase coupling /decoupling network;
> Equipped external magnetic field coil and accessory modules to meet IEC 61000-4-9 TEST.
Technical Parameters 1.2/50 μs、8/20 μs | |
Test Voltage Range |
0.5 kV ~ 8 kV ±10% |
Voltage Waveform |
Front time: 1.2μs ±30%; Pulse width: 50μs ±20% |
Test Current Range |
0.25 kA ~ 4 kA ±10%(2 ohm) |
Current Waveform |
Front time: 8μs ±20%; Pulse width: 20μs ±20% |
Source Impedance |
2 ohm, and 12 ohm to select |
Output Polarity |
+, -, +/- |
Pulse Period |
6 s ~ 180 s (the min. depends on the test voltage) |
No. Of Tests |
1 ~ 999 |
Peak voltage monitor |
BNC output : 1000 V:1 V; LCD display |
Peak current monitor |
BNC output : 500 A:1 V; LCD display |
Triggering Method |
Automatic / manual / external triggering |
Test mode |
Test parameter scheduling setting |
Technical Parameters 10/700 μs、5/320 μs | |
Test Voltage Range |
0.5 kV ~ 8 kV ±10% |
Voltage Waveform |
Front time: 10μs ±30%; Pulse width: 700μs ±20% |
Current Waveform |
Front time: 5μs ± 20%; Pulse width: 320μs ±20% |
Source Impedance |
15 ohm, and 40 ohm to select |
Output Polarity |
+, -, +/- |
Pulse Period |
11 s ~ 180 s (the min. depends on the test voltage) |
No. Of Tests |
1 ~ 999 |
Triggering Method |
Automatic / manual / external triggering |
Test mode |
Test parameter scheduling setting |
Technical Parameters 1.2/50 μs | |
Test Voltage Range |
0.5 kV ~ 8 kV ±10% |
Voltage Waveform |
Front time: 1.2μs ±30%; Pulse width: 50μs ±20% |
Source Impedance |
500 ohm |
Output Polarity |
+, -, +/- |
Pulse Period |
6 s ~ 180 s (the min. depends on the test voltage) |
No. Of Tests |
1 ~ 999 |
Peak voltage monitor |
BNC output : 1000 V:1 V; LCD display |
Triggering Method |
Automatic / manual / external triggering |
Test mode |
Test parameter scheduling setting |
General Parameters | |
Display |
5.7-inch colorful touch screen |
Operating Power Supply |
AC 110 V / 220 V±10%, 50 Hz / 60 Hz (AC 220 V in China) |
Fuse |
6 A |
Max Power |
200 W |
User storage space |
Infinite(PC) |
Communication Method |
Ethernet and RJ 45 |
Operating State Indicators |
Front panel LED, LCD |
Malfunction Detection |
Malfunctions will be shown on LCD while the operation will be stopped. |
Monitor output way |
1 meter coaxial-line |
Dimension |
6 U |
Weight |
Approx. 55 kg |
Operating Temp. |
15℃ ~ 35℃ |
Operating Humidity |
45% ~ 75% |
Operating Air Pressure |
86kPa ~ 106kPa |
Standard Accessories |
Power line, Test lines, Ground line, User manual , Coaxial-line, Fuses |
Optional Accessories |
1. External coupling/decoupling network SPN series: IEC 61000-4-5 SPN 2216S (220 V/16 A single phase coupling/decoupling network) SPN 3816T&SPN 3832T (380 V/16 A&380V /32 A three-phase coupling/decoupling network) SPN 38100T(380 V/100 A three-phase coupling/decoupling network) SPN 6916T&SPN 6932T (690 V/16 A &690V /32 A three-phase coupling/decoupling network) |
2. Signal/Communication lines coupling/decoupling network: IEC 61000-4-5 CDN 405T8A1(surge CDN for shielded asymmetric communication lines, 8 lines, including 4 lines tests) CDN 405M40-5(surge CDN for unshielded asymmetric communication lines, 2 lines tests) CDN 405AF4(surge CDN for unshielded asymmetric communication lines, 4 lines tests) CDN 405AF8-C(surge CDN for unshielded asymmetric high communication lines, 8 lines tests) |
3. Pulsed magnetic field converter PMC 1200, as per IEC 61000-4-9 |
4. Filed coil: TCXS111: Single turn coil, 1 m×1 m IEC 61000-4-8 TCXS113: three turns coil, 1 m×1 m IEC 61000-4-8 |
5. Differential probe VCF-80 test voltage: 8 kV (Attenuation 1000:1) |
6. Broadband current monitoring pliers : CM 0220M Attenuation : 0.01 V/A; |
7. PC software: Corelab With PC installed WIN 7, WIN 8 and WIN 10, it can be easily operated to make the measurement, based on the customized test program. It can identify any device with automatic configuration. It can easily generate test reports. |