Lightning surge simulator CWS 600G is generated during thundering weathers or opening/closing of electrical switches, which can bring adverse effects on all types of electrical equipment and devices that are directly or indirectly connected, as per IEC/EN 61000-4-5 and GB/T 17626.5 standards.
Voltage can be reach 6 kV, operate simply and scheduled test.
Features:
> 5.7-inch colorful touch screen;
> Voltage can reach 6 kV;
> Generate 1.2/50μs and 8/20μs high voltage pulse waveforms;
> Source impedance for 2 ohm;
> Detection of peak voltage / current, displayed on LCD;
> Test sequencing and scheduling, easy test setting;
> equipped External three-phase coupling /decoupling network;
Technical Parameters | |
Test Voltage Range |
0.3 V ~ 600 V ±10% |
Voltage Waveform |
Front time: 1.2μs ±30%; pulse width: 50μs ±20% |
Test Current Range |
0.15 A ~ 300 A±10% |
Current Waveform |
Front time: 8μs ±30%; pulse width: 20μs ±20% |
Source Impedance |
2 ohm |
Output Polarity |
+, -, +/- |
Pulse Period |
6 s ~ 99 s (the min. depends on the test voltage) |
No. Of Tests |
1 ~ 999 |
Peak voltage monitor |
BNC output : 1000 V:1 V; LCD display |
Peak current monitor |
BNC output : 500 A:1 V; LCD display |
Triggering Method |
Automatic / manual / external triggering |
Test mode |
Test parameter scheduling setting |
General Parameters | |
Display |
5.7-inch colorful touch screen |
Operating Power Supply |
AC 110 V / 220 V±10%, 50 Hz / 60 Hz (AC 220 V in China) |
Fuse |
6 A |
Max Power |
200 W |
Communication Method |
Ethernet and RJ 45 |
Operating State Indicators |
Front panel LED, LCD |
Malfunction Detection |
Malfunctions will be shown on LCD while the operation will be stopped. |
Dimension |
19-inch/ 6 U |
Weight |
Approx. 40 kg |
Operating Temp. |
15℃ ~ 35℃ |
Operating Humidity |
45% ~ 75% |
Operating Air Pressure |
86kPa ~ 106kPa |
Standard Accessories |
Power line, Test lines, Ground line, User manual , Coaxial cable, Fuses |
Optional Accessories |
External coupling/decoupling network SPN series: SPN 22xxS (single phase 220 V 32/100/300 A) SPN 38xxT (three-phase 380 V 32/100/300 A); SPN 69xxT (three-phase 690 V 32/100/300 A) |
Isolation transformer DG-4.4 kVA |
Differential probe VCF-80 (Attenuation 1000:1) |
Broadband current monitoring pliers : CM 0220M Attenuation : 0.01 V/A; |
PC software: Corelab With PC installed WIN 7, WIN 8 and WIN 10, it can be easily operated to make the measurement, based on the customized test program. It can identify any device with automatic configuration. It can easily generate test reports. |