SPN 38100T20A&20B High voltage and high power lightning surge coupling/decoupling network, meet the full range test requirements, can be combined with S10C2000, CWS 2000MS for different waveform
testing. The maximum surge combined wave test voltage is 20kV, 10kA, and the maximum 8/20μs current wave is 20kA. Meet AC/DC power supply, EUT maximum load capacity AC 380V 100A three-phase five-wire, DC 380V 100A.
Features:
> EUT maximum voltage AC 380V DC 380V 100A ;
> Scheduling Settings, to achieve automatic network switching function;
> Scheduling Settings, to achieve automatic network switching function;
> 8/20μs current wave up to 20KA;
> Arbitrary line phase Angle superposition.
Comply with IEC 61000-4-5 lightning surge immunity test technical parameters |
|
Three-phase Fully automatic coupling/decoupling network |
Conform to the EN/IEC 61000-4-5, GB/T 17626.5 lightning surge wave test Voltage up to 20kV (1.2/50μs) Current up to 10kA (8/20μs) Note: The actual output pulse voltage value of the coupling/decoupling network depends on the set value of the pulse generator |
Phase Losking |
Any line - line,line - ground phase Angle superimposed |
Coupling Path |
L1、L2、L3、N、Arbitrary combination L1(DC+)、N(DC-)DC paths |
Coupled Switching Mode |
Automatic Switching |
Coupling Capacitor |
9uF (line-to-ground) 18uF (line-to-line) |
Coupling Resistance |
10 ohm (wire-to-ground) 0 ohm (wire-to-line) |
EUT Load Capacity |
Max AC 380V、100A;Max DC 380V、100A; |
EUT Injection Residual Pulse Voltage |
Not more than 15% of the applied test pulse voltage or twice the peak rated voltage of the coupling/decoupling network |
Comply with IEC 61643-11 pulse current immunity test technical parameters |
|
Manual coupling/decoupling network |
Conform to the EN/IEC 61643-11、GB /T 18802.11 Coupled pulse current wave test Current up to 20kA (8/20μs) Note: The actual output pulse voltage value of the coupling/decoupling network depends on the set value of the pulse generator |
Output Current |
Up to 20kA(8/20us) |
Phase Losking |
Any line - line,line - ground phase Angle superimposed |
Coupling Path |
L1、L2、L3、N、Arbitrary combination L1(DC+)、N(DC-)DC paths |
Coupled Switching Mode |
Automatic Switching |
Coupled Apparatus |
Gas Discharge Tube |
EUT Load Capacity |
Max AC 380V、100A;Max DC 380V、100A; |
EUT Injection Residual Pulse Voltage |
Not more than 15% of the applied test pulse voltage or twice the peak rated voltage of the coupling/decoupling network |
General Parameters |
|
Working Power Supply |
AC 110V/220V±10%,50/60Hz±5% |
Fuse |
6A |
Maximum Power Consumption |
200W |
Auxiliary Interface |
D-sub 25p |
Grounding Connection Mode |
Use flat grounding line |
Dimension |
35U |
Weight |
Approx 200Kg |
Ambient Temperature |
15-35℃ |
Relative Humidity |
45% - 75% |
Atmospheric Pressure |
86kPa – 106kPa |
Standard Accessories |
Power supply line, Testing line, Grounding line, 25-core data line, factory inspection report, User Manual. |