The photovoltaic impulse voltage generator PVSG 3000 is designed according to the requirements of IEC 61730-2: 2016 (MST14) impulse voltage test, which meets the requirements of 1.2/50 μs waveform test of photovoltaic panels in the range of 20 nF - 170 nF. There are 11 gears to select, the test voltage is 2 kV ~30 kV, and the impulse voltage waveform parameters meet the requirements of IEC 60060-1 and GB/T 16927.1 standards.
Equipped with a capacitive load box for waveform calibration, which can simulate the capacitive load of photovoltaic panels. With the help of Corelab software, PVSG 3000 can remotely control the test process and generate calibration reports.
Features:
> Output voltage up to 30 kV ;
> Suitable for 20 nF-170 nF capacitive load,11 groups of gears to be selected;
> As per IEC 61730-2 2016 MST14;
> Built-in surge voltage measurement module, viewing waveform via oscilloscope is available;
> Built-in peak voltage monitor function;
> Ethernet, RJ45 interface for PC remote control and test report print;
General Parameters |
|
Display Screen |
5.7 TFT touch screen |
Working Power |
AC 110 V/220 V(±10%),50 Hz /60 Hz(Default in mainland China:220 V) |
Fuse |
6 A |
Max. Power |
200 W |
Communication Mode |
Ethernet LAN、RJ45 |
Safety Loop |
Stop working when the safety circuit is not closed |
Failure Detection |
The failure information will be displayed on LCD in front panel when failure occurs and interrupt the working of instrument. |
Earthing Mode |
Flat earth line |
Dimension |
PVSG 3000 : 8U PVCL 3000A : 5U PVCL 3000B : 5U |
Weight |
PVSG 3000 : 44 kg PVCL 3000A : 29 kg PVCL 3000B : 30 kg |
Ambient Temperature |
15 ℃ ~ 35 ℃ |
Relative Humidity |
45% ~ 75% |
Atmospheric Pressure |
86 kPa ~ 106 kPa |
Technical Parameters |
|
Standard |
IEC 61730-2: 2016 MST14 |
Test Voltage |
2 kV ~ 30.0 kV |
Calibration voltage |
4 or 8 kV ~ 30.0 kV ±3%; Initial voltage Depend on the load capacitance |
Rise Time |
1.2 μs±30% |
Duration |
50 μs±20% |
Polarity |
Positive, negative |
Waveform forming network |
Following Load capacitance |
Capacitance range |
20 nF to 170 nF, total of 11 gears, manually selected (short plug) 20 nF – 25 nF , 22.5 nF ±3% 25 nF – 30 nF , 27.5 nF ±3% 30 nF – 35 nF , 32.5 nF ±3% 35 nF – 40 nF , 37.5 nF ±3% 40 nF – 50 nF , 45 nF ±3% 50 nF – 60 nF , 55 nF ±3% 60 nF – 75 nF , 67.5 nF ±3% 75 nF – 95 nF , 85 nF ±3% 90 nF – 115 nF , 105 nF ±3% 115 nF – 140 nF , 127.5 nF ±3% 140 nF – 170 nF , 155 nF ±3% |
Repetition Rate |
8 s ~ 9999 s (The shortest time depends on test voltage) |
Counter |
1~ 9999 |
Trigger Mode |
Manual, Auto, External Trigger |
Measurement |
Monitor via coaxial port on front panel: 10 V @ 30 kV |
Peak Value Acquisition |
Display on touch screen, MAX : 30 kV |
Low-voltage Protection |
When the pulse voltage does not reach the set value, the test process stops |
Charging Display |
Count-down display |
Standerd Accessories |
User Manual, Test line, short-circuit plug, Earth line, 3-core power line, fuses (Spare parts),PVCL 3000A&PVCL 3000B , Test Box |
Optional Accessories |
PC control software:Corelab Windows 7, Windows 8 and Windows 10 are supported, including various operating functions and standard libraries. Users can easily control the test equipment remotely, complete the test work, and automatically configure it to help users flexibly generate test reports. |