Home|product
Chinese
search
x
    Product Menu

    PRODUCTS

    EMC General Test Equipments
    + Multifunctional Immunity Simulator
    + ESD Simulators
    + EFT/Burst Simulators
    + Surge Simulator
    + CDN for Power Line in Transient Immunity Test
    + CDN for Communication Cable in Transient Immunity Test
    + Radio-Frequency Conducted Simulator
    + CDN for RF Conducted Immunity Test
    + EM Clamp
    + Power Frequency Magnetic Field Simulator
    + AC/DC Magnetic Field Simulator
    + Pulse Magnetic Field Simulators
    + Damped Oscillatory Magnetic Field Simulator
    + Power Fail Simulator
    + DC Power Fail Simulator
    + Ring Wave Simulators
    + Fast/Slow Damped Oscillatory Wave Simulator
    + Common-Mode Conducted Immunity Simulator
    + Software
    Automotive EMC Test Equipments
    + Automotive ESD Simulator
    + Transient Immunity Simulator
    + Automotive Load Dump Simulator
    + Automotive Voltage Variation Simulator
    + Vehicle-mounted Arbitrary Waveform Simulator
    + ISO 7637-4
    + Automotive Transient Disturbance Simulator
    + Automotive BCI Test System
    + Low Frequency Magnetic Field Immunity Test System
    + Automobile Transient Pulse Simulator
    + High Voltage Noise Simulator
    + Vehicle Power Supply Circuit Surge Simulator
    + Vehicle Multimedia Voltage Disturbance Simulator
    + Ripple Signal Generator
    + Voltage Ripple Disturbance Simulator
    + Electro-mobile Vehicles Pulse Disturbance Generato
    + Automotive Spark Simulator
    + Electric Vehicle High Voltage Performance Test System
    + Artificial Network
    + Balanced / Unbalanced Transformers
    + Capacitance Coupling Clamp
    + Stripline
    + TEM Cell
    + Automotive Immunity Test Software
    + Calibration Accessories
    + Low-k Dielectric Material for Laboratory Test
    Military Test Equipment
    + Electrostatic Sensitivity for Electric Initiating
    + 300KV ESD Testing System
    + MIL-STD-461 Series/ GJB 151、181 Series
    + Spike Surge Voltage Simulator
    + Line Impedance Stabilization Network
    Lightning Effect Test Equipments
    + High Voltage Attachment Points Partition Test System
    + Lightning Direct Effect Test System
    + Lightning Indirect Effect Test System for Airborn Equipment
    + Voltage Spike Test System
    + Induced Signal Susceptibility Test System
    System Integration
    + General EMI Test System
    + General EMS Test System
    + Automotive EMI Test System
    + Automotive EMS Test System
    + Military EMI Test System
    + Military EMS Test System
    + Anechoic Chamber
    High Voltage Test Equipments
    + Impulse Current Test System
    + Impulse Current Generator
    + Surge Simulator
    + Coupling /Decoupling Network
    + Decoupling Network
    + Action Load Network Power
    + SPD Testers
    + Customization for HV Test Equipment
    + Impulse Voltage Test System
    + Measurement/Control Software
    + Accessories
    Product Compliance Test Equipment
    + Product Compliance Tester for Communication Power
    + Power Induction/Contact Simulator
    + High Power Short Time Overcurrent Simulator
    + Pulse Voltage Withstand Tester
    + High Voltage Pulse Simulator
    Customization for Non-EMC Equipment
    + Switching Device for Capacitor Endurance Test
    Agency Equipment
    + EMI Receiver
    + Power Amplifier
    + RF Accessories
    + Current Injection Probe
    ANSI Standards
    CISPR Standards
    EN Standards
    GB/T Standards
    GJB Standards
    IEC Standards
    ISO Standards
    ITU-TK Standards
    Other standards
    QC Standards
    SJT Standards
    TY-T Standards
    UL Standards
    YD-T Standards
    HOME>Products>Lightning Effect Test Equipments>Lightning Indirect Effect Test System for Airborn Equipment >Indirect Lightning Induced Transient Susceptibility Test System LSS 160SM6 & ETS 160MB
      Indirect Lightning Induced Transient Susceptibility Test System LSS 160SM6 & ETS 160MB
      Model:LSS 160SM6 & ETS 160MB

      Profile

      Indirect Lightning Induced Transient Susceptibility Test System LSS 160SM6 & ETS 160MB are designed according to RTCA/DO-160 Section 22, The LSS 160SM6 is capable of generating waveforms 1,4 and 5A/5B, and ETS 160MB is of waveforms 2, 3 and 6.
      PDFConsultation

      Online customized according to your needs>>

        Share
      • Feature
      • Standard
      • Parameter
      • Fitting
      • Services
      • Video
      When an aircraft is flying in severe convection environment, it will be frequently affected by lightning stroke, which will generate transient induced voltage or current on circuits and cables of airborne equipment, such phenomenon is called indirect lightning effect. It may make the aircraft get out of control, even bring about fuselage fire and other serious accidents. For safety reasons, the airborne equipment must be designed properly and tested completely to ensure the system and equipment with critical safety function to perform normally and its flight security when the aircraft is influenced by lightning stroke.
      The LSS 160SM6 and ETS 160MB test systems are designed according to RTCA/DO-160 Section 22, The LSS 160SM6 is capable of generating waveforms 1,4 and 5A/5B, and ETS 160MB is of waveforms 2, 3 and 6. Both test level are from 1 to 5 for pins injection test and cable bundle test; Additionally, the test system is not only meet the test requirement of lightning induced transients conducted susceptibility in MIL-STD-461G CS117, but also the A/B/C/D EUT pulse injection level requirement in GJB 8848: 2016 is satisfied.
      The ETS 160MB test system includes various test auxiliary equipment to make it convenient to conduct tests, such as coupling transformer, power blocking device, transient blocking device, pin injection probe, external DC capacitor etc. What’s more, the Corelab software is also available for test remote control, which makes your test easy and convenient.

      Features:
      > Modular design, the waveform module is detachable;
      > Capable of generating 6 kinds of waveforms and performing pins injection test and cable bundle test;
      > 5.7” color touch screen with easy and distinct operation control;
      > Phase synchronization function in signal pins & power pins-direct injection method;
      > Corelab software are available for remote control;

      • GJB 8848-2016
      • MIL-STD-461G
      • AECTP 250
      • AECTP 500
      • RTCA/DO-160G S22
      • HB 6167.24

      Technical Parameters for LSS 160SM6

      Technical Parameters—Current Waveform 1

      Cable Bundle Cable Induction

      For tests as per DO-160G S22, MIL-STD-461G CS117(WF2/1) etc.

      Coupling Mode

      Cable Induction (CI)

      Output Module

      W1 CI/GI

      Current Waveform 1

      6.4 μs ± 20 % / 69 μs ± 20 %

      Single Stroke Output

      50 A ~ 3500 A (-0%~+20%);

      Output Impedance0.5 Ω

      Multiple Stroke Output

      50 A ~2000 A (-0%~+20%) (first stroke); Output Impedance1 Ω

      25 A ~ 1000 A (-0%~+50%) (subsequent stroke);

      Output Impedance1 Ω

      Number of Subsequent Pulses

      1 ~ 14 (or 1 ~ 30)

      Interval Time of Subsequent Pulses

      10 ms ~ 200 ms,

      random mode is available

      Polarity

      positive or negative

      Number of Test Times

      1 ~ 99

      Test Repetition

      30 s ~ 60 s

      Coupler

      LCT- L5

      Technical Parameters—Current Waveform 1

      Cable Bundle Ground Injection

      For tests as per DO-160G S22 etc.

      Coupling Mode

      Ground Injection (GI)

      Output Module

      W1 CI/GI

      Current Waveform 1

      6.4 μs ± 20 % / 69 μs ± 20 %

      Single Stroke Output

      50 A ~ 3500 A (-0%~+20%);

      Output Impedance0.5 Ω

      Multiple Stroke Output

      50 A ~ 2000 A (-0%~+20%) (first stroke); Output Impedance1 Ω

      25 A ~ 1000 A (-0%~+50%)  (subsequent stroke);

      Output Impedance1 Ω

      The Number of Subsequent pulses

      1 ~ 14 (or 1 ~ 30)

      Interval Time of Subsequent Pulses

      10 ms ~ 200 ms,

      random mode is available

      Polarity

      positive or negative

      Number of Test Times

      1 ~ 99

      Test Repetition

      30 s ~ 60 s

      Maximum EUT Power Supply

      AC 230 V / 32 A 50/60 Hz;

      DC 230 V/32 A

      Coupler

      LCT- L5

      Technical Parameters—Voltage Waveform 4

      Signal Pins & Power Pins Direct Injection

      For tests as per DO-160G S22 etc.

      Coupling Mode

      Pins Direct Injection (PDI)

      Output Module

      W4 PI

      Output Impedance

      5 Ω ± 10 %

      Voltage/Current Waveform 4

      6.4 μs ± 20 % / 69 μs ± 20 %

      Output Voltage

      50 V ~ 3400 V (-0%~+10%), (open circuit)

      Output Current

      10 A ~ 680 A (-0%~+10%),

      (short circuit)

      Polarity

      positive or negative

      Number of Test Times

      1 ~ 99

      Test Repetition

      30 s ~ 60 s (shortest time depends on output amplitude)

      EUT Power Supply

      Max. 230 V

      EUT Frequency

      Max. 800 Hz

      Power Blocking Device

      Greater than peak value of signal or power voltage (optional)

      Technical Parameters—Voltage Waveform 4

      Cable Bundle Ground Injection

      For tests as per DO-160G S22

      Coupling Mode

      Ground Injection (GI)

      Output Module

      W4 CI/GI

      Voltage Waveform 4

      6.4 μs ± 20 % / 69 μs ± 20 %

      Single Stroke Output

      50 V ~ 3400 V (-0%~+20%);

      Output Impedance0.5 Ω

      Multiple Stroke Output

      25 V ~ 1000 V (-0%~+20%) (first stroke);

      Output Impedance0.5 Ω

      10 V ~ 500 V (-0%~+50%)  (subsequent stroke);

       Output Impedance0.5 Ω

      Number of Subsequent pulses

      1 ~ 14 (or 1 ~ 30)

      Interval Time of Subsequent Pulses

      10 ms ~ 200 ms,

      random mode is also available

      Polarity

      positive or negative

      Number of Test Times

      1 ~ 99

      Test Repetition

      30 s ~ 60 s

      EUT Power Supply

      Max. AC 230 V / 32 A 50/60 Hz;

      DC 230 V/32 A

      Coupler

      LVT-1

      Technical Parameters—Voltage Waveform 4

      Cable Bundle Cable Injection

      For tests as per DO-160G S22, etc.

      Coupling Mode

      Cable Induction (CI)

      Output Module

      W4 CI/GI

      Voltage Waveform 4

      6.4 μs ± 20 % / 69 μs ± 20 %

      Single Stroke Output

      50 V ~ 3400 V (-0%~+20%);

      Output Impedance0.5 Ω

      Multiple Stroke Output

      25 V ~ 1000 V (-0%~+20%) (first stroke);

      Output Impedance0.5 Ω

      10 V ~ 500 V (-0%~+50%) (subsequent stroke);

      Output Impedance0.5 Ω

      Number of Subsequent pulses

      1 ~ 14(or 1 ~ 30)

      Interval Time of Subsequent Pulses

      10 ms ~ 200 ms,

      random mode is also available

      Polarity

      positive or negative

      Number of Test Times

      1 ~ 99

      Test Repetition

      30 s ~ 60 s

      Coupler

      LVT-1

      Technical Parameters—Voltage Waveform 5A

      Signal Pins & Power Pins Direct Injection

      For tests as per DO-160G S22

      Coupling Mode

      Pins Direct InjectionPDI

      Output Module

      W5A PI

      Output Impedance

      1 Ω ± 10 %

      Voltage/

      Current Waveform 5A

      40 μs ± 20 % / 120 μs ± 20 %

      Output Voltage

      50 V ~ 3200 V (-0%~+10%) open circuit

      Output Current

      50 A ~ 3200 A  (-0%~+10%) short circuit

      Polarity

      positive or negative

      Number of Test Times

      1 ~ 99

      Test Repetition

      30 s ~ 60 s (shortest time depends on output amplitude)

      EUT Power Supply

      Max. 230 V

      EUT Power Frequency

      Max. 800 Hz

      Power Blocking Device

      Greater than peak value of signal or power voltage (optional)

      Technical Parameters—Current Waveform 5A

      Cable Bundle Cable Induction

      For tests as per DO-160G S22, MIL-STD-461G CS117(WF4/5A) etc.

      Coupling Mode

      Cable Induction (CI)

      Output Module

      W5A CI/GI

      Current Waveform 5A

      40 μs ± 20 % / 120 μs ± 20 %

      Single Stroke Output

      50 A ~ 10000 A (-0%~+20%);

      Output Impedance0.3 Ω

      Multiple Stroke Output

      50 A ~ 2000 A (-0%~+20%) (first stroke);

      Output Impedance0.3 Ω

      25 A ~ 1000 A (-0%~+50%)  (subsequent stroke);

      Output Impedance0.3 Ω

      Number of Subsequent pulses

      1 ~ 14 (or 1 ~ 30)

      Interval Time of Subsequent Pulses

      10 ms ~ 200 ms,

      random mode is also available

      Polarity

      positive or negative

      Number of Test Times

      1 ~ 99

      Test Repetition

      30 s ~ 60 s

      Coupler

      LCT- L5

      Technical Parameters—Current Waveform 5A

      Cable Bundle Ground Injection

      For tests as per DO-160G S22, MIL-STD-461, CS117 (WF4/5A) etc.

      Coupling Mode

      Ground Injection (GI)

      Output Module

      W5A CI/GI

      Current Waveform 5A

      40 μs ± 20 % / 120 μs ± 20 %

      Single Stroke Output

      50 A ~ 10000 A (-0%~+20%)

      Output Impedance0.3 Ω

      Multiple Stroke Output

      50 A ~ 2000 A (-0%~+20%) (first stroke);

      Output Impedance0.3 Ω

      25 A ~ 1000 A (-0%~+50%)  (subsequent stroke);

      Output Impedance0.3 Ω

      Number of Subsequent pulses

      1 ~ 14 (or 1 ~ 30)

      Interval Time of Subsequent Pulses

      10 ms ~ 200 ms,

      random mode is also available

      Polarity

      positive or negative

      Number of Test Times

      1 ~ 99

      Test Repetition

      30 s ~ 60 s

      EUT Power Supply

      Max. AC 230 V / 32 A 50/60 Hz; DC 230 V/32 A

      Coupler

      LVT- 5

      Technical Parameters—Voltage Waveform 5B

      Signal Pins & Power Pins Direct Injection

      For tests as per DO-160G S22 etc.

      Coupling Mode

      Pins Direct InjectionPDI

      Output Module

      W5B PI

      Output Impedance

      1 Ω ± 10 %

      Voltage/

      Current Waveform 5B

      50 μs ± 20 % / 500 μs ± 20 %

      Single Stroke Output

      50 V ~ 1600 V  (-0%~+10%) open circuit

      50 A ~ 1600 A  (-0%~+10%) short circuit

      Polarity

      positive or negative

      Number of Test Times

      1 ~ 99

      Test Repetition

      30 s ~ 60 s (shortest time depends on output amplitude)

      EUT Power Supply

      Max. AC/DC 230 V

      EUT Power Frequency

      Max. 800 Hz

      Power Blocking Device

      Greater than peak value of signal or power voltage (optional)

      Technical Parameters—Current Waveform 5B

      Cable Bundle Cable Induction

      For tests as per DO-160G S22

      Coupling Mode

      Cable Injection (CI)

      Output Module

      W5B CI/GI

      Current Waveform 5B

      50 μs ± 20 % / 500 μs ± 20 %

      Single Stroke Output

      50 A ~ 5000 A (-0%~+20%)

      Output Impedance0.3 Ω

      Multiple Stroke Output

      50 A ~ 2000 A (-0%~+20%) (first stroke);

      Output Impedance0.3 Ω

      25 A ~ 1000 A (-0%~+50%)  (subsequent stroke);

      Output Impedance0.3 Ω

      Number of Subsequent pulses

      1 ~ 14 (or 1 ~ 30)

      Interval Time of Subsequent Pulses

      30 ms ~ 200 ms,

      random mode is also available

      Polarity

      positive or negative

      Number of Test Times

      1 ~ 99

      Test Repetition

      30 s ~ 60 s

      Coupler

      LCT ~ L5

      Technical Parameters—Current Waveform 5B

      Cable Bundle Ground Injection

      For tests as per DO-160G S22

      Coupling Mode

      Ground Injection (GI)

      Output Module

      W5B CI/GI

      Current Waveform 5B

      50 μs ± 20 % /500 μs ± 20 %

      Single Stroke Output

      50 A ~ 5000 A (-0%~+20%);

      Output Impedance0.3 Ω

      Multiple Stroke Output

      50 A ~ 2000 A (-0%~+20%) (first stroke)

      Output Impedance0.3 Ω

      25 A ~ 1000 A (-0%~+50%)  (subsequent stroke);

      Output Impedance0.3 Ω

      Number of Subsequent pulses

      1 ~ 14 (or 1 ~ 30)

      Interval Time of Subsequent Pulses

      10 ms ~ 200 ms, random mode is also available

      Polarity

      positive or negative

      Number of Test Times

      1 ~ 99

      Test Repetition

      30 s ~ 60 s

      EUT Power Supply

      Max. AC 50/60 Hz 230 V / 32 A; DC 230 V/32 A

      Coupler

      LCT -L5

      List of waveform module and test type

      Waveform Module

      Test type

      W1 CI/GI

      Current waveform 1 – cable bundle cable induction test

      Current waveform 1 – cable bundle ground injection test

      W4 PI

      Voltage waveform 4 – signal pins & power pins direct injection method

      W4 CI/GI

      Voltage waveform 4 - cable bundle cable induction test

      Voltage waveform 4 - cable bundle ground injection test

      W5A PI

      Voltage waveform 5A – signal pins & power pins direct injection method

      W5A CI/GI

      Current waveform 5A – cable bundle cable induction test

      Current waveform 5A – cable bundle ground injection test

      W5B PI

      Voltage waveform 5B – signal pins & power pins direct injection method

      W5B CI/GI

      Current waveform 5B – cable bundle cable induction test

      Current waveform 5B – cable bundle ground injection test

      Technical Parameters for ETS 160MB

      Technical Parameters—Voltage Waveform 2

      Cable Bundle Cable Induction Tests

      Coupling Mode

      Cable Induction

      Rise Time

      < 100 ns

      Duration

      6.4 µs ± 20%

      Test Level for Single Stroke Tests

      50 V ~ 2000 V +20%, -0%

      Test Level for Multiple Stroke Tests

      50 V ~ 2000 V +20%, -0% (first stroke)

      25 V ~ 1000 V +50%, -0% (subsequent stroke)

      Polarity

      Positive or negative

      Coupling Transformer

      LVT-2

      Technical Parameters—Voltage Waveform 3 (1MHz)  Signal Pins & Power Pins Injection Tests

      Coupling Mode

      Pin injection

      Output Impedance

      25 Ω

      Frequency

      1 MHz± 20 %

      Decay Rate of  5th Waveshape

      25% ~ 75%

      Test Level for Single Stroke Tests

      100 V ~ 4500 V +10%, -0%

      4 A ~ 180 A +10%, -0% short-circuit current

      Polarity

      Positive or negative

      Phase Sync

      0° ~ 359°, resolution 1°

      EUT Power Supply

      Max. AC 230 V, DC ±50 V

      EUT Power Frequency

      800 Hz

      Technical Parameters—Voltage Waveform 3     (1 MHz-H) Cable Bundle Cable Induction Multiple Burst

      Coupling Mode

      Cable Induction

      Frequency

      1 MHz± 20 %

      Decay Rate of  5th Waveshape

      25% ~ 75%

      Output Impedance

      60 ohm

      Coupling Transformer

      LVT-2

      Technical Parameters—Voltage Waveform 3     (1 MHz) Cable Bundle Cable Induction Tests

      Coupling Mode

      Cable Induction

      Frequency

      1 MHz± 20%

      Decay Rate of   5th Waveshape

      25% ~ 75%

      Test Level for Single Stroke Tests

      50 V ~ 4500 V +20%, -0%

      Test Level for Multiple Stroke Tests

      50 V ~ 4500 V +20%, -0% (first stroke)

      50 V ~ 2250 V +50%, -0% (subsequent stroke)

      Polarity

      Positive or negative

      Coupling Transformer

      LVT-2

      Technical Parameters—Voltage Waveform 3     (10 MHz) Cable Bundle Cable Induction Tests

      Coupling Mode

      Cable Induction (CI)

      Frequency

      10 MHz± 20 %

      Decay Rate of   5th Waveshape

      25% ~ 75%

      Test Level for Single Stroke

      50 V ~ 4000 V +20%, -0%

      Test Level for Multiple Stroke

      50 V ~ 4000 V +20%, -0% (first stroke)

      50 V ~ 2000 V +50%, -0% (subsequent stroke)

      Polarity

      Positive or negative

      Coupling Transformer

      LVT-2

      Technical Parameters—Current Waveform 6     Cable Bundle Cable Induction Tests

      Coupling Mode

      Cable Induction

      Current Waveform

      5 A ~ 160 A

      Rise Time

      0.25 μs ±20%

      Duration

      4 μs ±20%

      Coupling Transformer

      LVT-3

      General parameters

      Display

      5.7” TFT touch screen

      Working Power

      220 V±10%50/60Hz

      Fuse

      10 A

      User’s Memory Space

      Infinite (PC)

      Communication Mode

      Ethernet LAN, RJ45

      Working Status Indication

      LED indication and LCD display on front panel

      Grounded Connection

      Flat earth line

      Waveform Output Terminal

      Banana plug line

      Dimension

      LSS 160SM6:

      600 mm(L) x 800 mm(W) x1800 mm(H) (35U rack)

      ETS 160MB:

      445 mm(L) x 690 mm(W) x600 mm(H) (4U×2)

      Weight

      LSS 160SM6: Approx. 150 kg

      ETS 160MB: 37 kg

      Ambient Temperature

      15 ℃ ~ 35 ℃

      Relative Humidity

      45% ~ 75%

      Atmospheric Pressure

      86 kPa ~ 106 kPa

      Accessories

      Fuse, Power line, Flat ground line, Test line, alligator clip, User Manual, Coaxial line

      Options (LSS 160SM6)

      1. Line Impedance Stabilization Network

      LISN AR 50

       

      The LISN AR 50 is used for isolating electric wave in cable bundle test and supply stable impedance for test system;

      Max AC 530 V, DC 600 V      I rms: 50 A;

      Frequency Range: 10 kHz ~

      400 MHz;

      2. Current Coupling Transformer

       LCT-L5

       

      The LCT-L5 is used for coupling current waveforms 1,5A,5B and meet the test requirement of single/multiple stroke (level 1~5) test;

      3. External DC Capacitor

      C3350 /C33400

       

      The C3350/C33400 is used together with LISN for conducting cable bundle tests; Maximum DC voltage is 400 V (general configuration is 50 V);

      Capacitance: 33000 μF;

      4. Voltage Coupling Transformer

      LVT-L5

       

      The LVT-1 is used for coupling voltage waveforms 4, 5A and meet the test requirement of single/multiple stroke (level 1 ~ 5) test;

      5. Power Blocking Device

      CN-1

       

       

      The CN-1 is used to isolate voltages at the pins of the EUT from the low generator impedance so as to protect the generator;

      The maximum isolating ac/dc voltage is 400 V;

      Meet the test requirement of powered EUT for conducting pins injection test of waveforms 4, 5A, 5B;

      6. Transient Blocking Device DN-416T

       

      The DN-416T is used to prevent EUT power supply from being damaged by pulses 4, 5A and 5B;

      EUT Maximum ac/dc power supply is 400 V 16 A three-phase, 0 ~ 400 Hz (common mode);

      Meet the test requirement of powered EUT for conducting pins injection test of waveforms 4, 5A, 5B;

      Note: Both LSS 160SM6 and ETS 160MB share the DN-416T.

      7. Transient Blocking Device DN-4200T

       

      The DN-4200T is used to prevent EUT power supply from being damaged by waveforms 4, 5A and 5B;

      Maximum AC/DC power supply is 400 V 200 A three phase, 50/60 Hz (common mode);

      Meet the test requirement of powered EUT for conducting pins injection test of waveforms 4, 5A, 5B;

      8.Digital Oscilloscope MDO3012 (Tektronix)

       

      Frequency 100 MHz;

      Sample Rate 1.25 GS/s;

      Record length 10 Mb;

      Note: Both LSS 160SM6 and ETS 160MB share the MDO3012.

      9. Wide-band Current Monitor

      CM 0302M

       

      The CM 0302M is used to measure W1, W4 and W5A/5B;

      Max. peak current 200 kA;

      Sensitivity 0.001 V/A;

      Frequency: 5 Hz ~ 2 MHz

      Current time product: 10 A·s;

      10. Differential Probe

      THDP0100

      (Tektronix)

       

      6 kV differential mode, 100 MHz;

      The THDP0100 is used for measuring voltage of all waveforms

      Note: Both LSS 160SM6 and ETS 160MB share the THDP0100.

      11. Corelab Software

       

      The software is used for remote control;

      Support connection with oscilloscope for monitoring waveforms;

      support generating test report;

      Note: Both LSS 160SM6 and ETS 160MB share the Corelab software.

      Options (ETS 160MB)

      1.  Coupling Transformer LVT-2

       

      The LVT-2 is used to couple voltage of waveform 2 and waveform 3 (1 MHz & 10 MHz);

      It satisfies single stroke, multiple stroke and multiple burst tests of cable bundle; Test level is from 1 to 5;

      Max. coupling voltage is 2000 V for W2;

      Max. coupling voltage is 4000 V for W3;

      2.  Coupling Transformer LVT-3

       

      The LVT-3 is used to couple current of waveform 6;

      It satisfies multiple burst tests of cable bundle; Test level is from 1 to 5;

      Max. coupling current is 160 A;

      3.  Power Blocking Device

      CN-2

       

      The CN-2 is used to isolate voltages at the pins of the EUT from the low generator impedance in waveform 3 pins direct injection test;

      4.  Handheld Pin Injection Probe

      HIP 5000

       

      The probe is used in pin injection tests of waveform 3 (1 MHz);

      Handheld structure design makes pin injection tests convenient;

      5.  Current Divider MCS 01

       

      The MCS 01 is used to measure current of waveforms 2, 3 and 6.

      6.   Wide-band Current Monitor

      CM 0103M

       

      The CM 0103M is used to measure W2, W3(1 & 10 MHz) and W6;

      Max. peak current 5 kA;

      Sensitivity 0.1 V/A;

      Frequency: 200 Hz ~ 20 MHz

      Current time product: 0.2 A·s;

      7.  35U rack

      ETS 160MB-35U

       

      The ETS 160MB-35U is used to place all devices and accessories to makes the storage in order;

      There are two main unit storage tanks and four waveform input modules storage tanks, and each tank having sliding rail, which makes it easy to insert or pull out the modules;

      Tel: +86 (0)512 6807 7192

      Video