The CST 10 series adopt all-in-one design, which integrate signal generator, RF power amplifier and RF power meter and each of them can be used independently. External power amplifier is optional as well as. Test electrical level required by standard can be obtained through driving coupling/decoupling network (CDN), electromagnetic clamp (EM-Clamp) and current clamp by internal wideband power amplifier (class A). The CST 10 series is controlled by PC software, so calibration and test can be conducted automatically, which greatly improves the test efficiency and system extendibility. The generated test result can be saved, printed or shared internally.
Features:
> Integrate signal generator, RF power amplifier and RF power meter into one;
> Support bulk current injection; optional current monitoring probe; support closed-loop test method;
> The creation of test templates makes software operation easy;
> USB interface for PC remote control;
IEC/EN 61000-4-6 and YY0505 CS Transient Immunity Test Setup
CST 1075 / CST 10150 (CST 1075E/ CST 10150E) |
|
Test Accessories (Voltage Method) |
|
CDN (Coupling / decoupling networks) |
|
Power line (M series) |
M1, M2, M3, M2+M3, M4, M5: Conform to the requirement of single-/three-phase power, Max. current reaches 300 A |
Unscreened balanced lines (T series) |
T2, T4, T8 |
Unscreened balanced lines (AF series) |
AF2, AF4, AF8 |
Screened cables (S series) |
S1, S2, S4, S8, S9, S25 |
Others |
RJ11, RJ11S, RJ45, RJ45S, USB-A, USB-B |
Calibration Jig 150 Ω-to-50 Ω |
CDN 100KIT Quantity:2 sets |
EM Clamp |
|
EM CL100 |
frequency range 100 kHz~1GHz, coupling factor < 3 d (150 kHz ~ 500 MHz), inner diameter 23 mm/32 mm calibration device EM CL100 KIT |
Attenuator |
|
Attenuator |
6 dB/80 W attenuator (CST 1075/ CST 1075E) 6 dB/200 W attenuator (CST 10150/ CST 10150E) |
CST 1075 / CST 10150 (CST 1075E/ CST 10150E) |
|
Test Accessories (Current Method) |
|
Current Injection Probe |
BCIP-400 Frequency range 4 kHz~400 MHz, |
Calibration Device 150 Ω-to-50 Ω |
BCI 100KIT Quantity:2 sets |
Calibration Jig |
BCICF-400 |
ISO 11452-4 BCI Test Setup
CST 1075B / CST 10150B |
|
Accessories for ISO 11452-4 BCI Test |
|
Attenuator |
30 dB/80 W Frequency Range DC~1 GHz |
Attenuator |
3 dB/80 W Frequency Range DC~1 GHz (CST 1075B) |
Attenuator |
3 dB/200 W Frequency Range DC~1 GHz (CST 10150B) |
50 Ω Load |
50 Ω/80 W Frequency Range DC~1 GHz |
Current Injection Probe |
BCIP-400 |
Calibration Device |
BCICF-400 Frequency Range DC~400 MHz |
Current Monitor Probe |
TWCM-500 Frequency Range 1 kHz~500 MHz |
Test Software |
EMC-S BCI |
Test Environment |
|
Conducted in a shielded room |
Test Table: 2,400 mm *1,000 mm *900 mm |
Ground Reference Plane: 2,400 mm *1,000 mm *1,200 mm |
RTCA DO-160 Section 20/ MIL-STD-461 CS114
CS114 Test Setup
CST 1075C / CST 10150C |
|
Accessories for GJB 151B CS 114 Test |
|
Attenuator |
30 dB/80 W Frequency Range DC~1 GHz |
Attenuator |
3 dB/80 W Frequency Range DC~1 GHz (CST 1075C) |
Attenuator |
3 dB/200 W Frequency Range DC~1 GHz (CST 10150C) |
50 Ω Terminal |
50 Ω/80 W Frequency Range DC~1 GHz |
Current Injection Probe |
BCIP-400 |
Calibration Device |
BCICF-400 Frequency Range DC~400 MHz |
Current Monitor Probe |
TWCM-500 Frequency Range 1 KHz~500 MHz |
Test Software |
EMC-S CS114 |
Test Environment |
|
Conducted in a shielded room |
Test Table: 2,400 mm *1,000 mm *900 mm |
Ground Reference Plane: 2,400 mm *1,000 mm *1,200 mm |
ISO 7637-4 Pulse A Test Setup
CST 1075D / CST 10150D |
|
Accessories for ISO 7637-4 Pulse A Test |
|
Attenuator |
30 dB/80 W Frequency Range DC~1 GHz |
Attenuator |
3 dB/80 W Frequency Range DC~1 GHz (CST 1075C) |
Attenuator |
3 dB/200 W Frequency Range DC~1 GHz (CST 10150C) |
Balanced/ Unbalanced Transformer |
TBT-200: 200 V; 1 MHz ~ 10 MHz; -3.3 dB; 50 Ω; |
HV Artificial Networks |
TANHV 200: 100 kHz ~ 150 MHz; 400 A; AC 700 V, DC 1 kV; 5μH || 50 Ω; |
50 Ω Load |
50 Ω/80 W Frequency Range DC~1 GHz |
HV Shielded Enclosure |
HVSE 400 |
HV Shielded Enclosure |
HVSE 200 |
HV Battery Load |
7637-4R500/120 3000 W |
Test Software |
EMC-S 7637-4 |
Test Environment |
|
Conducted in an unshielded room |
Test Table: 2,400 mm *1,000 mm *900 mm |
Ground Reference Plane: 2,400 mm *1,000 mm *1,200 mm |
Accessories |
User Manual, Test line, Fuse*2 (spare parts), power line, flat grounded line, attenuator, USB 2.0 printer line, BNC 50 Ω coaxial terminal load, RF cable |