The SEPN 100100T10 three-phase automatic coupling/decoupling network for EFT/Burst and surge immunity tests is designed according to test requirements of IEC/EN 61000-4-4 and IEC/EN 61000-4-5, features stable performance and convenient operation. The device is used together with CCS series, CWS series and EFT series of 3ctest. It can couple surge and EFT/Burst wave pulses onto three-phase mains supply system with voltage AC1000 V (three-phase-5-line)/DC 1500 V and current 100 A and can also be customized according to actual EUT load.
Features:
> EUT load capacity DC 1500 V 100 A, AC 1000 V 100 A three-phase-five-line;
> Current Range (0 A-100 A) is divided into 3 groups: 0 A-32 A, 32 A-63 A, 63 A-100 A, manual switching;
> Overcurrent protection;
> Test sequencing for voltage, polarity, phase sync angle etc., realizing fully automatic switching;
> Phase angles can superpose on arbitrary lines;
Technical Parameters – EFT/Burst |
|
Three-phase Fully-automatic CDN |
As per IEC/EN 61000-4-4; Voltage up to 4.2 kV; Note: due to the attenuation of CDN, the actual impulse voltage output from the port of CDN depends on the pulse voltage setting value in generators |
Phase Sync |
Any combination of L1, L2, L3, N, PE with any phases and angles |
Coupling Route |
Any combination of L1, L2, L3, N, PE |
DC Coupling Route |
L1 (DC+), N (DC-) |
Coupling Switching Mode |
automatic switching, test sequencing |
Coupling Capacitor |
33 nF |
Coupling Attenuation |
<2 dB |
Residual Pulse Voltage on EUT Injection Port |
≤ 10 % of test voltage; |
Technical Parameters - Surge |
|
Three-phase Fully-automatic CDN |
As per IEC/EN 61000-4-5; test voltage up to 10.0 kV(1.2/50 μs) , test current up to 5.0 kA(8/20 μs); Note: The actual pulse voltage output from CDN depends on the setting value in generators |
Phase Sync |
Any combination of L1, L2, L3, N, PE with any phases and angles |
Coupling Route |
Any combination of L1, L2, L3, N, PE |
DC Coupling Route |
L1 (DC+), N (DC-) |
Coupling Switching Mode |
automatic switching, test sequencing |
Coupling Capacitance |
9 μF、18 μF |
Coupling Resistance |
10 Ω、0 Ω |
Coupling Attenuation |
<2 dB |
Residual Pulse Voltage on EUT Injection Port |
≤ 15 % of test voltage or 2 times of rated peak voltage of CDN; |
General Parameters |
|
EUT Load Capacity |
Max AC 1000 V 100 A 50 Hz/60 Hz 3-phase-5-line |
Max DC 1500 V 100 A |
|
EUT Mains Switching Mode |
Automatic Switching |
Short-term Inrush Current |
Peak value 400 A |
Working Mains |
AC 110 V/220 V (±10 %),50 Hz /60 Hz (±5 %)(default AC 220 V 50 Hz in mainland China) |
Fuse |
6 A |
Max. Power Consumption |
200 W |
Auxiliary Port |
D-sub 25p |
Working Status Indication |
LED indication on front panel |
Grounded Connection Mode |
using flat earth line |
Dimension |
35U rack |
Weight |
Approx. 180 kg |
Ambient Temperature |
15 ℃ ~ 3 5 ℃ |
Relative Humidity |
45 % ~ 75 % |
Atmospheric Pressure |
86 kPa ~ 106 kPa |
Accessories |
||
1. 3-core power line |
5. Fuse (spare part) |
|
2. Testing line |
6. Coaxial line |
|
3. Earth line |
7. User manual |
|
4. CN25 line |
|
|
Optional Generators & Calibration Tools |
||
EFT 500x |
EFT/Burst generator, as per IEC 61000-4-4, max. burst output voltage 4.8 kV |
|
EFT 600x |
EFT/Burst generator, as per IEC 61000-4-4, max. burst output voltage 6.0 kV |
|
EFT 500x |
EFT/Burst generator, as per IEC 61000-4-4, max. burst output voltage 7.0 kV |
|
CWS 600x |
Surge generator; as per IEC 61000-4-5; max. pulse output voltage 6.0 kV (1.2/50 μs), output current 3.0 kA (8/20 μs) |
|
CWS 800x |
Surge generator; as per IEC 61000-4-5; max. pulse output voltage 8.0 kV (1.2/50 μs), output current 4.0 kA (8/20 μs) |
|
CWS 1000x |
Surge generator; as per IEC 61000-4-5; max. pulse output voltage 10.0 kV (1.2/50 μs), output current 5.0 kA (8/20 μs) |
|
CCS 600x |
Surge and EFT/Burst generator; As per IEC 61000-4-4, max burst output voltage is 4.8 kV As per IEC 61000-4-5, max. pulse output voltage 6.0 kV (1.2/50 μs), output current 3.0 kA (8/20 μs) |
|
CCS 1000x |
Surge and EFT/Burst generator; As per IEC 61000-4-4, max burst output voltage is 4.8 kV As per IEC 61000-4-5, max. pulse output voltage 10.0 kV (1.2/50 μs), output current 5.0 kA (8/20 μs) |
|
VCF-80 |
HV differential probe, for calibration of Surge generator (open-circuit voltage waveform); test voltage max 8 kV, attenuation: 1000:1; |
|
TR 5025 |
HV current transducer, for calibration of Surge generator (short-circuit current waveform); Test current max 20 kA, attenuation 100:1; |
|
Calibration Kit for EFT/Burst Generators |
TFB 50: input impedance 50 Ω, output impedance 50 Ω, attenuation 55 dB; TFB 1000: input impedance 1000 Ω, output impedance 50 Ω, attenuation 60 dB; Supplied with network adaptors and tool box. |