Home|product
Chinese
search
x
    Product Menu

    PRODUCTS

    EMC General Test Equipments
    + Multifunctional Immunity Simulator
    + ESD Simulators
    + EFT/Burst Simulators
    + Surge Simulator
    + CDN for Power Line in Transient Immunity Test
    + CDN for Communication Cable in Transient Immunity Test
    + Radio-Frequency Conducted Simulator
    + CDN for RF Conducted Immunity Test
    + EM Clamp
    + Power Frequency Magnetic Field Simulator
    + AC/DC Magnetic Field Simulator
    + Pulse Magnetic Field Simulators
    + Damped Oscillatory Magnetic Field Simulator
    + Power Fail Simulator
    + DC Power Fail Simulator
    + Ring Wave Simulators
    + Fast/Slow Damped Oscillatory Wave Simulator
    + Low Frequency Conducted Immunity Simulator
    + Software
    Automotive EMC Test Equipments
    + Automotive ESD Simulator
    + Transient Immunity Simulator
    + Automotive Load Dump Simulator
    + Automotive Voltage Variation Simulator
    + Vehicle-mounted Arbitrary Waveform Simulator
    + ISO 7637-4
    + Automotive Transient Disturbance Simulator
    + Automotive BCI Test System
    + Low Frequency Magnetic Field Immunity Test System
    + Automobile Transient Pulse Simulator
    + High Voltage Noise Simulator
    + Vehicle Power Supply Circuit Surge Simulator
    + Vehicle Multimedia Voltage Disturbance Simulator
    + Ripple Signal Generator
    + Voltage Ripple Disturbance Simulator
    + Electro-mobile Vehicles Pulse Disturbance Generato
    + Automotive Spark Simulator
    + Electric Vehicle High Voltage Performance Test System
    + Artificial Network
    + Balanced / Unbalanced Transformers
    + Capacitance Coupling Clamp
    + Stripline
    + TEM Cell
    + Automotive Immunity Test Software
    + Calibration Accessories
    + Low-k Dielectric Material for Laboratory Test
    Military Test Equipment
    + Electrostatic Sensitivity for Electric Initiating
    + 300KV ESD Testing System
    + MIL-STD-461 Series/ GJB 151、181 Series
    + Spike Surge Voltage Simulator
    + Line Impedance Stabilization Network
    Lightning Effect Test Equipments
    + High Voltage Attachment Points Partition Test System
    + Lightning Direct Effect Test System
    + Lightning Indirect Effect Test System for Airborn Equipment
    + Voltage Spike Test System
    + Induced Signal Susceptibility Test System
    System Integration
    + General EMI Test System
    + General EMS Test System
    + Automotive EMI Test System
    + Automotive EMS Test System
    + Military EMI Test System
    + Military EMS Test System
    + Anechoic Chamber
    High Voltage Test Equipments
    + Impulse Current Test System
    + Small impact current
    + Surge Simulator
    + Coupling /Decoupling Network
    + Decoupling Network
    + Action Load Network Power
    + SPD Testers
    + Customization for HV Test Equipment
    + Impulse Voltage Test System
    + Measurement/Control Software
    + Accessories
    Product Compliance Test Equipment
    + Product Compliance Tester for Communication Power
    + Power Induction/Contact Simulator
    + High Power Short Time Overcurrent Simulator
    + Pulse Voltage Withstand Tester
    + High Voltage Pulse Simulator
    Customization for Non-EMC Equipment
    + Switching Device for Capacitor Endurance Test
    Agency Equipment
    + EMI Receiver
    + Power Amplifier
    + RF Accessories
    + Current Injection Probe
    ANSI Standards
    CISPR Standards
    EN Standards
    GB/T Standards
    GJB Standards
    IEC Standards
    ISO Standards
    ITU-TK Standards
    Other standards
    QC Standards
    SJT Standards
    TY-T Standards
    UL Standards
    YD-T Standards
    HOME>Products>EMC General Test Equipments>CDN for Power Line in Transient Immunity Test >CDN for EFT/Burst and Surge Immunity Tests SEPN 3816TM
      CDN for EFT/Burst and Surge Immunity Tests SEPN 3816TM
      Model:SEPN 3816TM

      Profile

      The SEPN 3816TM three-phase manual coupling/decoupling networks are designed to be used together with CCS series
      PDFConsultation

      Online customized according to your needs>>

        Share
      • Feature
      • Standard
      • Parameter
      • Fitting
      • Services
      • Video
      The SEPN 3816TM three-phase manual coupling/decoupling networks are designed to be used together with CCS series, CWS series and EFT series of 3ctest to couple EFT/Burst and surge wave pulses onto mains supply system with voltage AC 380 V and current 16 A (3-phase-five-line) according to the requirement of IEC/EN 61000-4-4 and IEC/EN 61000-4-5 . Other voltage level and current level is available on customer request.

      Features:
      > EUT load capacity AC 380 V 16 A; 
      > Over-current protection;


      • IEC 61000-4-5
      • IEC 61000-4-4
      • IEC 61000-6-2
      • IEC 61000-6-1
      • GB/T 17626.5
      • GB/T 17626.4
      • EN 61000-4-5
      • EN 61000-4-4

      Technical Parameters – EFT/Burst

      Three-phase Manual CDNs

      Comply with IEC/EN 61000-4-4 EFT/Burst immunity test. Maximum test voltage up to 4.2 kV.

      Note: the actual output pulse voltage of CDNs is subject to the setting value of generator.

      Coupling Route

      Manually switch, L1, L2, L3, N, PE random combination route

      Coupling Capacitor

      Manually switch, 33 nF

      Coupling Attenuation

      <2 dB

      Residual Pulse Voltage of EUT Injection Port

      Not exceeding 10% of testing impulse voltage

      Technical Parameters - Surge

      Three-phase Manual CDNs

      Comply with IEC/EN 61000-4-5 surge combination wave tests. Maximum voltage up to 6.0 kV (1.2/50 μs) and maximum current up to 3.0 kA (8/20 μs).

      Note: the actual output pulse voltage of CDNs is decided by the setting value of pulse generators.

      Coupling Route

      Manually switch, L1, L2, L3, N, PE arbitrary combination route

      Coupling Capacitor

      Manually switch, 9 μF, 18 μF

      Coupling Resistor

      Manually switch, 10 Ω, 0 Ω

      Coupling Attenuation

      <2 dB

      Residual Pulse Voltage of EUT Injection Port

      Not exceeding 15% of testing impulse voltage or two times of peak rated voltage of CDNs.

      General Parameters

      EUT Load Capacity

      Max AC 380 V 16 A, 50 Hz/  60 Hz, 3-phase-5-line

      Working Power Source

      AC 110 V/220 V±10%50 Hz /60 Hz±5%  (AC 220 V 50 Hz in mainland China)

      Dimension

      19"/6U

      Weight

      Approx. 30 kg

      Ambient Temperature

      15  ~ 35

      Relative Humidity

      45% ~ 75%

      Atmospheric Pressure

      86 kPa ~ 106 kPa


      Accessories

      1. User Manual

      2. Power Supply Line

      3. Testing Line

      4. Grounded Line

      5. Coaxial Line

      6. Short-circuit Plug

      Optional Generators & Calibration Tools

      EFT 500x

      EFT/Burst generator, as per IEC 61000-4-4, max. burst output voltage 4.8 kV

      EFT 600x

      EFT/Burst generator, as per IEC 61000-4-4, max. burst output voltage 6.0 kV

      EFT 500x

      EFT/Burst generator, as per IEC 61000-4-4, max. burst output voltage 7.0 kV

      CWS 600x

      Surge generator; as per IEC 61000-4-5; max. pulse output voltage 6.0 kV (1.2/50 μs), output current 3.0 kA (8/20 μs)

      CWS 800x

      Surge generator; as per IEC 61000-4-5; max. pulse output voltage 8.0 kV (1.2/50 μs), output current 4.0 kA (8/20 μs)

      CWS 1000x

      Surge generator; as per IEC 61000-4-5; max. pulse output voltage 10.0 kV (1.2/50 μs), output current 5.0 kA (8/20 μs)

      CCS 600x

      Surge and EFT/Burst generator;

      As per IEC 61000-4-4, max burst output voltage is 4.8 kV

      As per IEC 61000-4-5, max. pulse output voltage 6.0 kV (1.2/50 μs), output current 3.0 kA (8/20 μs)

      CCS 1000x

      Surge and EFT/Burst generator;

      As per IEC 61000-4-4, max burst output voltage is 4.8 kV

      As per IEC 61000-4-5, max. pulse output voltage 10.0 kV (1.2/50 μs), output current 5.0 kA (8/20 μs)

      VCF-80

      HV differential probe, for calibration of Surge generator (open-circuit voltage waveform);

      test voltage max 8 kV, attenuation: 1000:1;

      TR 5025

      HV current transducer, for calibration of Surge generator (short-circuit current waveform);

      Test current max 20 kA, attenuation 100:1;

      Calibration Kit for EFT/Burst Generators

      TFB 50: input impedance 50 Ω, output impedance 50 Ω, attenuation 55 dB;

      TFB 1000: input impedance 1000 Ω, output impedance 50 Ω, attenuation 60 dB;

      Supplied with network adaptors and tool box.


      Tel: +86 (0)512 6807 7192

      Video