Technical Parameters – EFT/Burst |
|
|
Single-phase Automatic CDN
|
(As per IEC/EN 61000-4-4, ) Max. test voltage: 4.2 kV (Note: the actual output voltage is subject to the set value of the generator) |
|
Phase Sync. |
Any combination of L, N, PE with any phases and angles |
|
Coupling Paths |
Any combination of L, N, PE |
|
Switching of Coupling Paths |
Automatic, schedulable |
|
Coupling Capacitor |
33 nF |
|
Coupling Attenuation |
<2 dB |
|
Residual Surge Voltage at the EUT Injection Terminal |
<10% of the test voltage |
|
Technical Parameters - Surge |
||
Single-phase Automatic CDN
|
As per IEC/EN 61000-4-5, Max test voltage: 6.0 kV (1.2/50 μs), max. test current: 3.0 kA (8/20 μs) (Note: the actual output voltage is subject to the set value of the generator) |
|
Phase Sync. |
Any combination of L, N, PE with any phases and angles |
|
Coupling Paths |
Any combination of L, N, PE |
|
Switching of Coupling Paths |
Automatic, Schedulable |
|
Coupling Capacitor |
9 uF, 18 uF |
|
Coupling Resistor |
10 ohm, 0 ohm (standard or user-defined) |
|
Coupling Attenuation |
<2 dB |
|
Residual Surge Voltage at the EUT Injection Terminal |
<15% of test voltage, or <2 times of rated peak voltage of the CDN |
|
General Parameters |
||
EUT Load Capacity |
Max AC 250 V 50 A |
|
Max DC 100 V 50 A |
||
EUT Power Supply Switching Mode |
Automatic |
|
Power Supply |
AC 110 V / 220 V±10%,50/60 Hz ± 5% |
|
Fuse |
6 A |
|
Max Power |
200 W |
|
Auxiliary Terminal |
D-sub 25p |
|
Status Indicators |
Front panel LED |
|
Grounding Method |
Flat Grounding strap |
|
Dimension |
19"/22U |
|
Weight |
100 kg |
|
Ambient Temperature |
15 ℃~35 ℃ |
|
Relative Humidity |
45% ~ 75% |
|
Atmospheric Pressure |
86 kPa ~ 106 kPa |
Accessories |
|
User manual, Test line, Power line, Grounding line, fuse, Coaxial cable |
|
Optional Generators & Calibration Tools |
|
EFT 500x |
EFT/Burst generator, as per IEC 61000-4-4, max. burst output voltage 4.8 kV |
EFT 600x |
EFT/Burst generator, as per IEC 61000-4-4, max. burst output voltage 6.0 kV |
EFT 500x |
EFT/Burst generator, as per IEC 61000-4-4, max. burst output voltage 7.0 kV |
CWS 600x |
Surge generator; as per IEC 61000-4-5; max. pulse output voltage 6.0 kV (1.2/50 μs), output current 3.0 kA (8/20 μs) |
CWS 800x |
Surge generator; as per IEC 61000-4-5; max. pulse output voltage 8.0 kV (1.2/50 μs), output current 4.0 kA (8/20 μs) |
CWS 1000x |
Surge generator; as per IEC 61000-4-5; max. pulse output voltage 10.0 kV (1.2/50 μs), output current 5.0 kA (8/20 μs) |
CCS 600x |
Surge and EFT/Burst generator; As per IEC 61000-4-4, max burst output voltage is 4.8 kV As per IEC 61000-4-5, max. pulse output voltage 6.0 kV (1.2/50 μs), output current 3.0 kA (8/20 μs) |
CCS 1000x |
Surge and EFT/Burst generator; As per IEC 61000-4-4, max burst output voltage is 4.8 kV As per IEC 61000-4-5, max. pulse output voltage 10.0 kV (1.2/50 μs), output current 5.0 kA (8/20 μs) |
VCF-80 |
HV differential probe, for calibration of Surge generator (open-circuit voltage waveform); test voltage max 8 kV, attenuation: 1000:1; |
TR 5025 |
HV current transducer, for calibration of Surge generator (short-circuit current waveform); Test current max 20 kA, attenuation 100:1; |
Calibration Kit for EFT/Burst Generators |
TFB 50: input impedance 50 Ω, output impedance 50 Ω, attenuation 55 dB; TFB 1000: input impedance 1000 Ω, output impedance 50 Ω, attenuation 60 dB; Supplied with network adaptors and tool box. |