Technical Parameters |
||
|
Power Amplifier |
Signal Source |
Frequency Range |
DC 250 kHz |
DC 10 Hz - 250 kHz (sine wave) |
Output Power |
250 W (nominal) |
N/A |
Output Voltage |
50 V RMS, max 120 V (0 – 100 kHz); 30 V RMS, max 120 V (100 kHz – 250 kHz); |
±10 V |
Output Current |
5 A RMS (0 – 200 kHz); 4 A RMS (200 kHz – 250 kHz); |
N/A |
Output Impedance |
30 mΩ at 1 kHz |
N/A |
Protection System |
Short-circuit protection, superheating protection; |
N/A
|
DC Bias Voltage |
N/A |
0 – 10 V adjustable, in control of external DC amplifier |
General Parameters |
||
Power Supply |
AC 110 V / 220 V, 50 / 60 Hz (The default configuration is 220 V, 50 Hz for Mainland China) |
|
Input Power |
Max 500 W |
|
Connector Type |
Ethernet RJ45 for PC control or connection with PAWG 100 |
|
Operating Temp. |
15℃ - 35℃ |
|
Operating Humidity |
45% - 75% |
|
Dimension |
19”, 8 U |
|
Weight |
Approx. 18 kg |
Standard Accessories |
|||||
1 |
Radiation Ring |
TBR 100 |
1 pc |
120 mm, for magnetic field tests, In compliance with Ford EMC-CS:2009.1, RI 140 |
|
2 |
Magnetic Field Sensor |
TBM 100 |
1 pc |
To measure magnetic field strength |
|
3 |
Transformer Set |
CN 200 |
1 set |
Consisting of two audio transformers (the two primary / input sides are in cascade connection, while the two secondary / output sides are in parallel connection ), and one adjustable resistor of 0.5Ω / 250 W, used for low-frequency conducted disturbances tests as per Ford EMC-CS-2009.1 Fig. 18-6 Ground offset. |
|
4 |
Quality Guarantee |
1 pc |
N/A |
||
5 |
Factory Inspection Report |
1 pc |
N/A |
||
6 |
User Manual |
1 pc |
N/A |
||
Optional Accessories |
|||||
1 |
Measuring Unit |
Built-in type, options: voltage measure, current measure, magnetic field measure |
|||
Frequency Range |
10 Hz – 250 kHz |
||||
Measurement Accuracy |
Better than 5% |
||||
Disconnected Ahead Of The Pulse |
Used together with external current clamp; 10 mV / A : 1 mA – 30 A RMS; 100 mV / A : 10 mA – 300 A RMS; |
||||
Voltage Measurement |
17 mV – 70 V RMS |