Technical Parameters |
||||||||||||
Current Waveform |
8 / 20 μs |
10 / 350 μs |
||||||||||
Peak Output Current |
65 kA, 120 kA, 150 kA, 200 kA |
5 kA, 15 kA, 25 kA, 30 kA |
||||||||||
Front Time T1 |
8 μs ±10% |
<50 μs |
||||||||||
Tail Time T2 |
20 μs ±10% |
350 μs ±10% |
||||||||||
Reverse Overshooting |
<20% |
N/A |
||||||||||
Wave Front Oscillation |
<5% |
<5% |
||||||||||
Voltage Waveform Distortion |
<5% (sine wave) |
|||||||||||
Voltage Polarity |
+ / -, automatic switching |
|||||||||||
Switching Of Waveforms |
Automatic |
|||||||||||
Charging Time |
10 s – 999 s |
|||||||||||
Charging Voltage Instability |
<1% |
|||||||||||
External Sync. Input |
50 Hz |
|||||||||||
Triggering Method |
Automatic / manual, can be single-time triggering |
|||||||||||
Triggering Error Rate |
<1% |
|||||||||||
Triggering Range |
100% rated charging voltage |
|||||||||||
Phase Range |
0°- 360° |
|||||||||||
Operating Duty Test |
Built-in, 0 V – 500 V, 5 A continuous |
|||||||||||
Display |
10” TFT color touch screen |
|||||||||||
Measurement Accuracy |
3% |
|||||||||||
EUT Types |
MOV, TVS, GDT, SPD, power supply type SPD etc |
|||||||||||
EUT Residual Voltage |
<5kV |
|||||||||||
Optional Current Measurement |
Built-in test box, Ross coil, BNC output; |
|||||||||||
Optional Voltage Measurement |
Built-in test box, pure voltage divider, BNC output |
|||||||||||
Optional Oscilloscope |
MDO 3012 |
|||||||||||
Insulation Strength |
≤500 V RMS (common terminal to PE) |
|||||||||||
General Parameters |
||||||||||||
Operating Power Supply |
AC 220 V±10%, 50 Hz / 60 Hz, 10 A |
|||||||||||
Operating Temp. |
15℃ - 35℃ |
|||||||||||
Operating Relative Humidity |
45% - 75% |
|||||||||||
Grounding Resistor |
≤0.5Ω |
|||||||||||
Dimension of Test Room |
5 x 5 m (main body) plus 3 x 5 m (control unit) |
|||||||||||
Dimension of Operating Platform |
1,800 x 1,100 x 1,000 m |
|||||||||||
Option of Models |
||||||||||||
Models |
LCG 65C |
LCG 120C |
LCG 150C |
LCG 200C |
||||||||
8/20 Peak Value |
65kA |
120 kA |
150 kA |
200 kA |
||||||||
10/350 Peak Value |
5 kA |
15 kA |
25 kA |
30 kA |
||||||||
Stored Energy |
20 kJ |
74 kJ |
128 kJ |
200 kJ |
||||||||
8/20 Charging Voltage |
30 kV |
60 kV |
60 kV |
80 kV |
||||||||
10/350 Charging Voltage |
15 kV |
15 kV |
18 kV |
22 kV |
||||||||
Operating Power Supply |
AC 220 V, 32A |
AC 220 V, 50A |
AC 220 V, 50A |
AC 220 V, 100A |
||||||||
Weight |
1,500 kg |
2,000 kg |
2,500 kg |
3,500 kg |
||||||||
Other Waveforms |
||||||||||||
No. |
Waveform |
Type |
Max Output |
Charging Voltage |
Equivalent Output Impedance |
|||||||
A |
10/350 |
Current waveform |
50 kA |
20 kV |
0.4Ω |
|||||||
B |
4/10 |
Current waveform |
100 kA |
100 kV |
1Ω |
|||||||
C |
8/20 |
Current waveform |
250 kA |
100 kV |
0.4Ω |
|||||||
D |
10/1000 |
Current waveform |
20 kA |
15 kV |
0.5Ω |
|||||||
E |
100/1000 |
Current waveform |
20 kA |
15 kV |
0.5Ω |
|||||||
F |
1/10 |
Current waveform |
20 kA |
50kV |
2.5Ω |
|||||||
P |
Other waveforms can be customized |
|||||||||||
Note: The default configuration for each equipment of this series is equipped with two waveform modules. Other configuration can be customized. |