Technical Parameters |
||||||
Parameters for Voltage Waveform |
Open-Circuit Peak Voltage |
10 kV |
15 kV |
20 kV |
||
Open-Circuit voltage Waveform |
1.2±30%/50±20% μs |
|||||
Output Impedance |
6 Ω±10% |
|||||
Built-In Load Impedance |
50 Ω±10% |
|||||
Short-Circuit Peak Current |
1.65 kA |
2.5 kA |
3.3 kA |
|||
Parameters for Current Waveform |
Short-Circuit Current Waveform |
8±10%/20±10% μs |
||||
Output Impedance |
5 Ω±10% |
|||||
Built-In Load Impedance |
3 kΩ |
|||||
Short-Circuit Peak Current |
2 kA |
3 kA |
4 kA |
|||
Test Polarity |
Positive/Negative |
|||||
Coupling/ Decoupling Networks |
Power Supply |
Single-Phase/ Three-Phase |
Single-Phase Network |
|||
Control Method |
Auto |
|||||
Voltage |
Three-Phase AC 380 V16 A |
Single-Phase AC 220 V16 A |
||||
Installation Method |
Built-in |
|||||
Coupling |
Capacitor or Gap |
|||||
Decoupling |
Capacitor, inductance |
|||||
Power Supply |
AC 220 V 1 kVA |
AC 220 V 1.5 kVA |
AC 220 V 2 kVA |
|||
Dimension(Mm) |
600 *800*1750 |
600*800*1750 |
600*800*1750 |
|||
Weight(Kg) |
300 |
400 |
450 |
|||
General Parameters |
||||||
Ambient Temperature |
-10℃ - 40℃ |
|||||
Relative Humidity |
35%-85% RH(No condensation) |
|||||
Grounded Resistor |
Less than 0.5 Ω |
|||||
No conductive dust, no fire and explosion hazard, no corrosive gas. The voltage waveforms are sinusoids; waveform distortion is less than 5%. |