The CDN M4N/32 is designed according to IEC/EN 61000-4-6, which specifies clearly on the design and performance of coupling/decoupling networks. The CDN M4N/32 is applicable to three-phase (4-wire supply lines) mains supply systems.
Features:
>Maximum withstand voltage is 32 A;
>Applicable to three-phase (4-wire) supply lines;
Technical Parameters |
|
Model No. |
CDN M4N-32 |
Standard |
IEC/EN 61000-4-6 |
Frequency |
150 kHz ~ 230 MHz |
Max. AC Voltage (L-PE) |
250 V |
Max. DC Voltage (L-PE) |
400 V |
Max. Current |
32 A |
RF Input Interface(BNC) |
<30 V |
EUT Port Type |
4 mm Banana(L1/L2/L3/N) |
AE Port Type |
4 mm Banana(L1/L2/L3/N) |
Common Mode Impedance (EUT) |
|
150 kHz ~ 26 MHz |
150 Ω±20 Ω |
26 MHz ~ 80 MHz |
150 Ω +60 Ω /-45 Ω |
Voltage Division Coefficient(RF Input-EUT Port) |
|
150 kHz ~ 80 MHz |
9.5 dB±1 dB |
80 MHz ~ 230 MHz |
9.5 dB±2 dB |
Common mode Disturbances Suppression (RF Port / AE) |
|
150 kHz: |
>35 dB |
1.5 MHz: |
>55 dB |
30 MHz: |
>55 dB |
80 MHz: |
>40 dB |
230 MHz |
>20 dB |
General Parameters |
|
Weight |
Approx. 4.0 kg |
Dimension |
210 mm(L)×170 mm(W) × 115 mm(H) |
Enclosure Material |
Aluminum |
Ambient Temperature |
5°C ~ 40°C |
Relative Humidity |
20% ~ 80% |
Package Case |
Carton |
Optional Accessories |
|
CAL 100F |
150 Ω to 50 Ω Calibration device |
CAL 150F |
150 Ω Calibration device |
CDN ADP M4 |
Calibration adapter |