Technical Parameters |
|
Test Voltage |
Max 4.2 kV; (Note: the actual output value is subject to the set value of the generator) |
Coupling Paths |
Any combination of L1, L2, L3, N, PE |
Switching of Coupling Paths |
Manual; |
Coupling Capacitance |
33 nF; |
Coupling Attenuation |
< 2 dB; |
Residual Impulse Voltage at EUT Injection End |
Less than 10% of test voltage; |
EUT Load Capacity |
3-phase 5-wire, AC 380 V, 200 A; |
EUT Power Supply Injection |
Via banana plug; |
EUT Injection Method |
Via co-axial cable; |
Grounding Method |
Via flat grounding strap; |
General Parameters |
|
Weight |
Approx. 30 kg |
Ambient Temperature |
15 ℃ ~ 35 ℃ |
Relative Humidity |
35% ~ 85% RH(no condensation) |
Atmospheric Pressure |
75 kPa ~ 106 kPa |
Accessories |