Technical Parameters |
|
Waveform 1.2/50 μs, 8/20 μs |
|
Open-circuit voltage |
2~20 kV±10% |
Output voltage waveform |
1.2±30%、50 μs±20% |
Output impedance |
2 Ω |
Output short-circuit current |
1~10 kA±10% |
Output current waveform |
8/20 μs±20% |
Pulse Current Module (8/20 μs) |
|
Charging voltage |
2-10 kV |
Output voltage waveform |
8/20 μs±20% |
Output impedance |
0.5 Ω |
Output short-circuit current |
4~20 kA ±10% |
Pulse Current Module (10/350 μs) |
|
Charging voltage |
2-10 kV |
Output current waveform |
10(-10%+100%), 350 μs±20% |
Output impedance |
13 Ω |
Output short-circuit current |
0.15-0.75 kA |
Pulse Current Module (10/1000 μs) |
|
Charging voltage |
2-10 kV |
Output current waveform |
10(-10%+100%)/1000 μs±20% |
Output impedance |
40 Ω |
Output short-circuit current |
0.1-0.25 kA |
Pulse Voltage Module (1.2/50 μs) |
|
Charging voltage |
2-20 kV ±10% |
Output voltage waveform |
1.2/50 μs |
Output impedance |
500 Ω (to be customized) |
General Parameters |
|
Triggering mode |
Synchronous/asynchronous; Automatic/manual; Capable of single triggering |
Working power |
AC 110 V / 220 V ,(±10%),50/60 Hz |
Working temperature |
15-35 ℃ |
Working humidity |
45%-75% |
Working air pressure |
86 kPa - 106 kPa |
Dimension |
19”/35U(600x800x1820) |
Standard Accessories |
|
CWS 2000TS station 19” cabinet x 2 |
|
Manual x 1 |
|
Factory Inspection Report x 1 |
|
Quality Guarantee x 1 |
|
Testing Wire x 1 |
|
Power supply cable x 1 |
|
Fuse x 1 |
|
Optional Accessories |
|
Oscilloscope |
MDO 3012 |
Wide-band Current Monitor |
CM 0220M |
CDN |
3 phase or single phase CDN, e.g. SPN 3820T20M,AC 380 V 20 A, 20 kV, Manual superimposing |