Combination Waveform(1.2/50 μs & 8/20 μs) |
||
Open-circuit Voltage |
||
Peak Voltage |
500 V ~15 kV(±10%) |
|
Front Time |
1.2 μs (±30%) |
|
Duration Time |
50 μs(±20%) |
|
Short-circuit Current |
||
Peak Current |
250 A~7.5 kA(±10%) |
|
Rise Time |
8 μs (±20%) |
|
Duration Time |
20 μs(±20%) |
|
Virtual Impedance |
2 Ω±0.25 Ω |
|
Output Polarity |
Positive/Negative |
|
CDNs(Built-in/Externally) |
Single/three-phase fully automatically CDNs are available optionally. |
|
Voltage Waveform(1.2/50 μs) |
||
Output Voltage |
500 V ~15 kV(±10%) |
|
Output Impedance |
500 Ω±10% |
|
Output Polarity |
Positive/Negative or positive first and negative second |
|
Output Voltage Waveform |
1.2 μs±30%,50 μs±20% |
|
Communication Waveform(10/700 μs) |
||
Output Voltage |
500V~10kV ±10% |
|
Output Polarity |
Positive/Negative |
|
Output Voltage Waveform |
10/700(±20%)μs |
|
Output Current Waveform |
5/320(±20%)μs |
|
Output Impedance |
15 Ω, 40 Ω(25 Ω+15 Ω) |
|
Output Short-circuit Current |
12.5 A~250 A(±10%) |
|
CDNs(Externally) |
2-way 4-line and 4-way 8-line CDNs are available optionally. |
|
General Parameters |
||
Working Power Source |
AC 110 V/220 V (±10%),50/60 Hz (AC 220 V in Mainland China) |
|
Ambient Temperature |
15 ℃-35 ℃ |
|
Relative Humidity |
45%-75% |
|
Atmospheric Pressure |
86 kPa-106 kPa |
|
Grounded Resistance |
Not exceeding 0.5 Ω |
|
Dimension |
19” /35 U(600 mm×800 mm×1850 mm) |
|
Weight |
Approx. 200kg |
Optional Accessories |
||
Oscilloscope |
MDO 3012 |
Tektronix |
Wide-band Current Monitor |
CM 0220M |
|
Voltage Probe |
P 6015A |
Tektronix |
Control Software |
Corelab |
Supports Win Xp/7 |
Measurement Software |
MAS 3000 |
fiber optics communication |
CDNs |
SPN 4816SM15 |
Single-phase, 480 V, 16 A, Manual switching, 15 kV |