Almost all electrical equipment and devices can be affected by the unidirectional surges caused by over-voltages from switching and lightning transients. CWS x00G/SPN xxT series is a particularly designed system for the surge immunity tests for three phase EUTs with automatic switching of external CDN, and can also be used for pulsed magnetic field immunity tests. The products are in full compliance with CE and CCC requirements. The series includes 6 kV & 8 kV generators CWS 600G & CWS 800G, and SPN with EUT load capacity: AC 380V or 450 V, & 16 A – 100 A or customizable.
Features
> 5.7” color touch screen front panel operation;
> Surge voltage up to 6 kV/8 kV, surge current up to 3 kA/4 kA;
> Surge voltage/current monitoring on LCD display (optional);
> Fault detection (optional);
> Test sequencing, easy operation;
> External automatic 3-phase 5-wire CDN;
> Can be used for IEC 61000-4-9 tests with optional induction coils;
> RJ45 for PC control & test report printing.
General Parameters |
|
Display |
5.7” TFT color touch screen |
Operating power supply |
AC 110 V/220 V ±10%, 50/60 Hz |
Fuse |
6 A |
Max power |
250 W |
Storage space |
Unlimited (PC) |
Communication method |
Ethernet, RJ 45 |
External control method |
D-sub 25p |
External triggering input |
BNC, 5 V TTL |
CRO triggering input |
BNC, 5 V TTL |
Operation control input |
BNC, 5 V TTL |
External sync input |
45 Hz – 65 Hz, 20 V – 500 V between different terminals; 0 – 500 V between terminals & the case; |
Alarm indicators output |
0-220 V AC, 10 A; 0-48 V DC 3A (subject to the type of external signal indicators) |
Safety circuit |
No operation when the safety circuit is open |
Fault detection |
Shown on LCD display, operation will be stopped |
Operating status |
LED indicators on front panel, LCD display |
Grounding method |
Grounding strips |
Grounding connection |
Standard 1 m coaxial cable |
Dimension |
19“, 6U x 2 units |
Weight |
30 kg |
Operating temp. |
15 ℃ ~ 35 ℃ |
Operating relative humidity |
45% ~ 75% |
Operating air pressure |
86 kPa ~ 106 kPa |
Technical Parameters (IEC 61000-4-5) |
|
Test voltage |
0.3 kV–6.0 kV/8.0 kV, ±10% (CWS 600G/800G) |
Voltage waveform |
Tf: 1.2 μs ±30%, Td: 50 μs ±20% |
Test current |
0.15 kA – 3.0 kA/4.0 kA, ±10% |
Current waveform |
Tf: 8 μs ±20%, Td: 20 μs ±20% |
Source impedance |
2 Ω |
Output polarity |
+, -, +/- |
Coupling capacitance |
9 μF, 18 μF |
Coupling resistance |
10 Ω, 0 Ω (as per IEC standards or customized) |
Surge period |
5 s – 99 s (the min. depends on test voltage) |
Test times |
1 – 999 |
Triggering mode |
Automatic, manual or external triggering |
Sync. |
0° - 360°, 1°step or by random steps |
External CDN |
|
Model No. |
SPN 38XXT |
Coupling Capacitance |
9 μF / 18 μF |
Decoupling Inductance |
1.5 mH |
Coupling Mode |
Automatic, test sequence |
EUT load capacity |
Max:AC 380 V 16 A/32 A 3-phase-5-wire |
Accessories |
3-core power cable、Short-circuit plug、Testing wires、Grounding cables、Fuse、Coaxial cables、User manual |
Optional Accessories |
1. Coupling/Decoupling Networks |
CDN 405AF8 CDN for interconnected cables (unshielded asymmetrical lines) (90 V GDT; test voltage 6 kV (or customizable); AE/EUT terminals: RJ 45; current withstand: 1 A; decoupling residual voltage: 90 V;) |
CDN 405T8 CDN for interconnected cables (unshielded symmetrical lines) (90 V GDT; test voltage 6 kV (or customizable); AE/EUT terminals: RJ 45; current withstand: 1 A; decoupling residual voltage: 90 V;) |
CDN 405T8A1 CDN for interconnected cables (unshielded symmetrical lines) (90 V GDT; test voltage 6 kV (or customizable); AE/EUT terminals: RJ 45; current withstand: 1 A; decoupling residual voltage: 90 V;) |
2. PC control software CoreLab |
Supports Windows XP/7; easy test setting, test sequencing, rich test standards library; test report generation. |