VTE 100 is designed according to ISO 7637-2 for performing conductive voltage emission tests. VTE 100-MS is a standard automotive relay, which is used for measuring transient emission with amplitude over 400 V, while VTE100- ES is a semi-conductive electronic switch for amplitude less than 400 V.
Features:
> Meet the requirement of ISO 7637-2;
>The position of ES switch and MS switch is interchangeable;
> Testing voltage up to 60 V DC, continuous current100 A;
> Switch on/off time is displayed on Nixie tube, with auto/manual/external trigger characters;
> Built-in RS resistor, switch automatically;
> With function of over-heating alarm;
General Parameters |
|
Working Power |
AC 110 V/240 V(±10%),50 Hz /60 Hz |
Fuse |
6 A |
Max. Power Consumption |
100 W |
EUT Voltage Monitoring Output |
BNC,1:1 coaxial port output |
Paralleled Resistor |
EXT., 10 Ω, 20 Ω, 40 Ω, 120 Ω |
Trigger Mode |
Auto, single, external |
Mode Selection |
Mechanical Switch, Electronic Switch |
Grounded Connection Mode |
<=10 mm Banana plug line |
Max. Test Voltage |
60 V DC |
Max. Test Current |
100 A |
Temperature Alarm |
80 ℃ |
Dimension(L*W*H) |
330 mm*320 mm*205 mm(socket not included) |
Weight |
Approx. 11 kg |
Ambient Temperature |
15℃–35℃ |
Relative Humidity |
45%–75% |
Atmospheric Pressure |
86 kPa–106 kPa |
Artificial Network Parameters |
|
Frequency |
0.1 MHz ~100 MHz |
Capacitor |
0.1 uF |
Impedance |
5uH||50Ω, as per impedance graph in ISO 7637-2 |
ZPA |
<5mΩ |
Parameters for VTE 100-ES |
|
Switch ON/OFF Time |
0.01 s~99.99 s+(10%+10 ms) |
Voltage Drop |
<2 V@25 A, typical 2.3 V@100 A |
Switching Time |
300 ns+20%@load 50 uH/0.6 Ω |
Transient Protective Voltage |
440 V |
Dimension(L*W*H) |
120 mm*215 mm*155 mm(socket not included) |
Weight |
Approx. 3.2 kg |
Parameters for VTE 100-MS |
|
Switch ON/OFF Time |
0.05 s~99.99 s+(10%+10 ms) |
Max. Switch Current |
100 A |
Contact |
High purity silver contact material, no suppression across relay contact |
Dimension(L*W*H) |
120 mm*215 mm*155 mm(socket not included) |
Weight |
Approx.1.7 kg |
VTE –CAES (Optional Module) |
|
Input Voltage |
13.5 V |
Ambient Temperature |
15 ℃-35 ℃ |
Dimension(L×W×H) |
520 mm×520 mm ×590 mm |
Weight |
Approx. 16 kg |
Calibration load 0.6 Ω and 50 μH for the verification of the electronic switch characteristic. |
Accessories |
User manual, Testing wire, Impedance calibration jig, Connecting pole, Data wire, Fuse*2, Power line, Standard M4 plug |