EFT/Burst test as per IEC 61000-4-4 |
|
Standard |
IEC/EN 61000-4-4, GB/T 17626.4 |
Test Voltage |
0.25 kV ~ 4.2 kV, ± 10% |
Polarity |
Positive, negative |
Pulse Frequency |
0.1 kHz ~ 1000 kHz |
Synchronization |
0° ~ 360°, 1° step or random |
Coupling Network |
Three-phase automatic CDN (see optional models) |
Surge immunity test as per IEC 61000-4-5 |
|
Standard |
IEC/EN 61000-4-5、GB/T 17626.5 |
Test Voltage |
0.3 kV ~ 6 kV,±10% |
Test Current |
0.15 kA ~3 kA,±10% |
Current Waveform |
Front time: 8us±20%, time to half value: 20 μs±20% |
Source Output Impedance |
2 ohm |
Output Polarity |
+/-/alternative |
Coupling Capacitance |
9 μF, 18 μF |
Coupling Resistance |
10 ohm, 0 ohm, IEC standard mode or customized mode |
Synchronization |
0° ~ 360°, 1° step or random |
Coupling Network |
Three-phase automatic CDN (see optional models) |
General Parameters |
|
Working Mains |
AC110 V / 220 V, ±10%, 50/60 Hz (default AC 220 V in China) |
External Control |
25 Pin D-Bus |
Working Indicator |
LED front panel |
Detection Output |
1 m standard coaxial cable |
Dimension |
19 inch/6U |
Weight |
approx. 50 kg |
Ambient Temperature |
15 ℃~35 ℃ |
Relative Humidity |
45% ~ 75% |
Atmospheric Pressure |
86 kPa ~ 106 kPa |
Basic equipment |
|
Four-core plug, Three-core power cord, Four-core socket, Test line, Ground line, User manual, Fuse, Coaxial cable |
|
Optional Models |
|
1. SEPN series |
CDN for surge and burst |
SEPN 2216S |
Single phase-3-wire AC 220 V 16 A, Max 250 V |
SEPN 2232S |
Single phase-3-wire AC 220 V 32 A, Max 250 V |
SEPN 3816T |
Three-phase-5-wire AC 380 V 16 A, Max 440 V |
SEPN 3832T |
Three-phase-5-wire AC 380 V 32 A, Max 440 V |
SEPN 6932T |
Three-phase-5-wire AC 690 V 16 A, Max 750 V |
2. SPN series |
CDN for lightening surge |
SPN 3816T |
Three-phase-5-wire AC 380 V 16 A, Max 440 V |
SPN 2232S |
Single phase-5-wire AC 220 V 32 A, Max 250 V |
3. EFTN series |
CDN for burst |
EFTN 3832T |
Three-phase-5-wire AC 380 V 32 A, Max 440 V |
4. CCC 100 |
Capacitance coupling clamp |
5. EMS Lab |
Test software |