> low frequency magnetic field immunity test as per ISO 11452-8, frequency range: 15Hz – 150kHz
> internal magnetic field calibration device
Parameters |
|
Model |
HHS5024-12 |
Max. current |
60 A, 5 min. |
Rated current |
30 A continuous |
coil space |
200 mm, 250 mm, 300 mm |
following data when the space is 200mm |
|
Max. magnetic field strength |
2500 A/m, 5 min |
Rated magnetic field strength |
1288 A/m continuous |
Magnetic field strength when coil current is 1A |
42.93 A/m |
Current |
152.66 dBμA/m |
current needed for 1 A/m |
23.29 mA |
transfer factor between current and strength |
32.66 dB/m |
coil diameter |
400 mm |
size |
0.38 m x 0.58 m x 0.42 m |
frequency range |
15 - 500 kHz |
Inductance(each coil): |
120 μH |
Inductance(a pair of coil): |
240-260 μH |
resistance(each coil): |
47.5 mW |
capacitance(a pair of coil): |
52 pF |
Harmonic frequency(a pair of coil) |
> 1.4 MHz |
weight |
10.2 kg |
accessories(included in the basic equipment) |
|
connection cable |
2 |
calibrated clamp for magnetic field |
1 |
calibration report |
1 |
user manual |
1 |