Home|product
Chinese
search
x
    Product Menu

    PRODUCTS

    EMC General Test Equipments
    + Multifunctional Immunity Simulator
    + ESD Simulators
    + EFT/Burst Simulators
    + Surge Simulator
    + CDN for Power Line in Transient Immunity Test
    + CDN for Communication Cable in Transient Immunity Test
    + Radio-Frequency Conducted Simulator
    + CDN for RF Conducted Immunity Test
    + EM Clamp
    + Power Frequency Magnetic Field Simulator
    + AC/DC Magnetic Field Simulator
    + Pulse Magnetic Field Simulators
    + Damped Oscillatory Magnetic Field Simulator
    + Power Fail Simulator
    + DC Power Fail Simulator
    + Ring Wave Simulators
    + Fast/Slow Damped Oscillatory Wave Simulator
    + Low Frequency Conducted Immunity Simulator
    + Software
    Automotive EMC Test Equipments
    + Automotive ESD Simulator
    + Transient Immunity Simulator
    + Automotive Load Dump Simulator
    + Automotive Voltage Variation Simulator
    + Vehicle-mounted Arbitrary Waveform Simulator
    + ISO 7637-4
    + Automotive Transient Disturbance Simulator
    + Automotive BCI Test System
    + Low Frequency Magnetic Field Immunity Test System
    + Automobile Transient Pulse Simulator
    + High Voltage Noise Simulator
    + Vehicle Power Supply Circuit Surge Simulator
    + Vehicle Multimedia Voltage Disturbance Simulator
    + Ripple Signal Generator
    + Voltage Ripple Disturbance Simulator
    + Electro-mobile Vehicles Pulse Disturbance Generato
    + Automotive Spark Simulator
    + Electric Vehicle High Voltage Performance Test System
    + Artificial Network
    + Balanced / Unbalanced Transformers
    + Capacitance Coupling Clamp
    + Stripline
    + TEM Cell
    + Automotive Immunity Test Software
    + Calibration Accessories
    + Low-k Dielectric Material for Laboratory Test
    Military Test Equipment
    + Electrostatic Sensitivity for Electric Initiating
    + 300KV ESD Testing System
    + MIL-STD-461 Series/ GJB 151、181 Series
    + Spike Surge Voltage Simulator
    + Line Impedance Stabilization Network
    Lightning Effect Test Equipments
    + High Voltage Attachment Points Partition Test System
    + Lightning Direct Effect Test System
    + Lightning Indirect Effect Test System for Airborn Equipment
    + Voltage Spike Test System
    + Induced Signal Susceptibility Test System
    System Integration
    + General EMI Test System
    + General EMS Test System
    + Automotive EMI Test System
    + Automotive EMS Test System
    + Military EMI Test System
    + Military EMS Test System
    + Anechoic Chamber
    High Voltage Test Equipments
    + Impulse Current Test System
    + Small impact current
    + Surge Simulator
    + Coupling /Decoupling Network
    + Decoupling Network
    + Action Load Network Power
    + SPD Testers
    + Customization for HV Test Equipment
    + Impulse Voltage Test System
    + Measurement/Control Software
    + Accessories
    Product Compliance Test Equipment
    + Product Compliance Tester for Communication Power
    + Power Induction/Contact Simulator
    + High Power Short Time Overcurrent Simulator
    + Pulse Voltage Withstand Tester
    + High Voltage Pulse Simulator
    Customization for Non-EMC Equipment
    + Switching Device for Capacitor Endurance Test
    Agency Equipment
    + EMI Receiver
    + Power Amplifier
    + RF Accessories
    + Current Injection Probe
    ANSI Standards
    CISPR Standards
    EN Standards
    GB/T Standards
    GJB Standards
    IEC Standards
    ISO Standards
    ITU-TK Standards
    Other standards
    QC Standards
    SJT Standards
    TY-T Standards
    UL Standards
    YD-T Standards
      Compact immunity simulator CCS 600
      Model:CCS600

      Profile

      CCS600 is an intelligent multifunctional compact immunity (EMS) test system, as per all the requirements of international standards and product standards for transient pulse, surge and voltage dip.
      PDFConsultation

      Online customized according to your needs>>

        Share
      • Feature
      • Standard
      • Parameter
      • Fitting
      • Services
      • Video


      CCS 600 is an intelligent multifunctional compact immunity (EMS) test system, which meets all the requirements of international standards and product standards for transient pulse, surge and voltage dip. Its test voltage is up to 6 kV. CCS series are the best choice for full compliance immunity test solutions. With built-in fully automatically single-phase CDN, it not only meets the immunity testing requirements of CE and CCC certification for single-phase EUTs, but also be capable of performing three-phase-five-line EUTs tests by using automatically controlled external CDNs (up to 100 A) of our company. Various enclosures needed are available to satisfying types of needs such as power frequency magnetic field tests.


      Features:
      > 5.7” color touch screen
      > Surge failure detection
      > Data acquisition of surge voltage and current       
      > Test sequence function
      > Built-in multifunctional testing modules
      > Built-in single-phase fully automatically CDN,AC 250 V 16 A;DC-1 (resistive load) 250 V 16 A
      > Optional for external three-phase CDN modules
      > Ethernet and RJ45 ports, used for PC remote control, test report documentation and print etc.


      • IEC 61000-4-5
      • IEC 61000-4-9
      • IEC 61000-4-4
      • IEC 61000-4-8
      • IEC 61000-4-11
      • IEC 61000-4-29
      • IEC 61008-1
      • IEC 61009-1
      • GB/T 17626.5
      • GB/T 17626.4
      • GB/T 17626.8
      • GB/T 17626.9
      • GB/T 17626.11
      • GB/T 17626.29
      • EN 61000-4-5
      • EN 61000-4-9
      • EN 61000-4-4
      • EN 61000-4-11
      • EN 61008-1
      • EN 61009-1
      • EN 61543
      • EN 61000-4-8
      • EN 61000-4-29
      • ANSI/IEEE C62.41

      General Parameters

      Display Screen

      5.7” TFT color touch screen

      Power Supply

      AC 110 V/220 V(10%)50 Hz /60 Hz, (±5%) default AC 220 V 50 Hz in mainland China

      Fuse

      6 A

      Max. Power Consumption

      200 W

      Memory Space

      InfinitePC

      Communication Mode

      Ethernet, RJ45

      Dimension

      19”/6U

      Weight

      Approx. 41 kg

      Ambient Temperature

      15-35

      Relative Humidity

      45%-75%

      Atmospheric Pressure

      86 kPa-106 kPa

       

       

      EFT/burst Tests as per IEC 61000-4-4

      Test Voltage

      0.25 kV-4.8 kV(±10%

      Source Impedance

      50 Ω

      Polarity

      Positive, negative, alternative

      Rise Time

      5 ns(±30%), 50 Ω load, 1000 Ω load

      Pulse Waveform

      5/50 ns, 50 Ω and 1000 Ω load

      Pulse Frequency

      0.1 kHz-1000 kHz

      Pulse Duration

      50 ns±30%, 50 Ω load

      Burst Duration

      0.075 ms-750 ms

      50 ns-15/+100 ns1000 Ω load

      Test Duration

      1 s-9999 s

      Burst Cycle

      11 ms-9999 ms

      Synchronization

      0° - 360°, 1° step or random

      Trigger Mode

      Automatic, manual or external trigger

      CDN

      Internal single phase automatic CDN: Single-phase-3-line                    AC 220 V 16 A Max 250 V

      Surge Tests as per IEC61000-4-5

      Test Voltage

      0.3 kV-6 kV±10%

      Test Current

      0.15 kA-3 kA±10%

      Voltage Waveform

      Front time: 1.2 μs (±30%), Time to half value: 50 μs (±20%)

      Source Output Impedance

      2 Ω

      Current Waveform

      Front time: 8 μs (±20%), Time to half value:20 μs (±20%)

      Coupling Capacitance

      9 μF, 18 μF

      Polarity

      Positive, negative, alternative

      Pulse Cycle

      5 s-180 s (the shortest depends on test voltage

      Coupling Resistance

      10 Ω, 0 Ω coupling resistor Either IEC standard mode or customized mode is optional

      Number of Test

      1–999

      Surge Voltage and Current Peak Detection

      Front panel BNC output,   surge voltage: 1000 V:1 V           Surge current :500 A:1 V          3 digits on display

      Synchronization

      0° - 360°, 1° step or random

      Trigger Mode

      Automatic, manual or external trigger

      CDN

      Built-in single phase automatic CDN

      Single-phase-3-line                   AC 220 V 16 A Max. 250 V

       PFMF Tests as per IEC61000-4-8 with optional module MFT 400/1200 or VMT series

      Magnetic Field Strength

      TCXS 111 Single-turn coil:     1 A/m -100 A/m (continuous)

      100 A/m -400 A/m (1 s-10s in short time)

      TCXS 113 Single-turn coil   1 A/m -300 A/m (continuous)

      300 A/m -1200 A/m (1 s-10 s in short time)

      Current Distortion Rate

      <5%

      Current Waveform

      50 Hz/60 Hz sine wave

      Operating Current Range for Short Time  

      120 A-500 A

      Continuous Operating Current Range

      1 A-120 A

      Test Duration

      1 s-28800 s

      Magnetic Field Output Accuracy

      Deviation 1dBminimal magnetic field intensity like 1A/m needs to be adjusted manually before tests.

      Waveform Interval

      1 s-9999 s

      Coil Size

      1000 mm *1000 mm or others

      Trigger mode

      Auto, Manual, External signal trigger

      Coil Turn

      Single-turn /three-turn

      Coil shape

      Rectangle or others

      Output Magnetic Field Strength

      Test Sequencing setup

       

       

      Pulse Magnetic Field Tests as per IEC 61000-4-9 with optional module PMC 1200

      Output Magnetic Field Range

      100 A/m-1200 A/m

      Waveform

      Rise time:6.4 μs (±30%);            duration: 16 μs (±30%)

      Output Current

      100 A-2000 A

      Polarity

      Positive, negative, alternative

      Synchronization

      0°- 360°, 1°step or random

      Pulse Cycle

      5 s-99 sthe shortest depends on test current

      Trigger Mode

      Automatic, manual or external trigger

      Coil Shape

      Rectangle

      Number of Test

      1-999

      Model of Coil

      TCXS 111

      Coil Size

      1000*1000mm

      Output Magnetic Field Strength

      Test sequencing setup

      Coil Turn

      Single

       

       

       

      Power Fail Tests as per IEC 61000-4–11 (with Optional Module VVT or VMT series) & IEC 61000-4-29

      EUT Max. Voltage

      250 V AC, 220 V DC

      EUT Max. Current

      AC/DC 16 A continuous current;        AC 20 A continuous 5 s;

      40 A continuous 3 s;

      500 A impulse current

      EUT Current and Voltage Measurement

      LCD display, BNC terminal: voltage 100:1, current 10 A:1 V

      Dip Level

      0%-100%for VVT/VMT series

      0%40%70%80%(for VVTxxxxSFseries)

      Interruption level

      0%

      Dip and Interruption Interval

      5 ms-9999 ms

      Dip and Interruption Duration

      0.1-9999 cycle or 1 ms-9999 ms

      Dip and Interruption Rise/Fall Time

      1 µs -5 µs (100 Ω load)

      Dip and Interruption Test Duration

      1 s-9999 s

      Time of Voltage Variation Decreasing

       

      500 ms-9999 ms (50%-100%) or abrupt (same with rise/ fall time for dips and 

      interruption)

      1000 ms-9999 ms (0%-100%) or abrupt (same with rise/ fall time for dips and 

      interruption)

      Voltage Variation Level

      0-100%

      Duration after Voltage Variation Decreasing

      10 ms-99999 ms

      Time of Voltage Variation Increasing

      500 ms-9999 ms50%-100%

      1000 ms-9999 ms0%-100%

      Trigger Mode

      Automatic, manual or external trigger

      Synchronization

      0°- 360°, 1° step or random

       

       

      Models Selection

      Name

      Model

      IEC 61000-4-4

      IEC 61000-4-5

      IEC 61000-4-8

      IEC 61000-4-9

      IEC 61000-4-11

      IEC 61000-4-29

      CDN single- phase-3-line

      Compact Immunity Test System

      CCS 600

      EFT/Burst CDN

      EFTN 3816T

       

       

       

       

       

       

      Surge CDN

      SPN 3816T

       

       

       

       

       

      EFT/Burst and Surge CDN

      SEPN 3816T

       

       

       

       

      SEPN 3832T

       

       

       

       

      Power Frequency Magnetic Module

      MFT 400

       

       

       

       

       

      MFT 1200

       

       

       

       

       

      AC Voltage Dips, Short Interruption and Variation Module

      VVT 2216S

       

       

       

       

       

      VVT 2216SV

       

       

       

       

       

      Power Fail and Power Frequency Magnetic Module

      VMT 2216S

       

       

       

       

      VMT 2216SV

       

       

       

       

      Pulsed Magnetic Field Converter

      PMC 1200

       

       

       

       

       

      Accessories

      User Manual, Fuse×2spare parts, Flat Grounding Wire, Radio-Frequency Wire, Testing Wire, Power Supply Wire