>Ethernet and RJ45 interface for PC remote control and test report printing;
Test 1: Technical Parameters for High-frequency Pulse Voltage Waveform |
|
Output Voltage (VIp) |
73 V±2 V(connected to 25 Ω±0.5 Ω load) 80 V±2 V (connected to 1 kΩ±0.02 kΩ load) |
Rise Time (tr) |
≤10 μs |
Time Constant (τ) |
52 μs±5 μs |
Pulse Repetition (t) |
5 ms |
Test Time |
10 min |
Test 2: Technical Parameters for Giant Pulse Voltage Waveform |
|
Output Voltage (VGP) |
100 V±2 V(connected to 25 Ω±0.5 Ω load) 110 V±2 V(connected to 1 kΩ±0.02 kΩ load) |
Rise Time tr |
≤1 ms |
Time Constant (τ) |
0.188 s±0.004 s |
Pulse Repetition |
1 min |
Counter |
1-99 |
Test 3: Technical Parameters for High-frequency Pulse + Surge Voltage |
|
High-frequency Pulse |
|
Pulse Voltage Peak Value (VIp) |
73 V±2 V(connected to 25 Ω±0.5 Ω load) 80 V±2 V(connected to 1 kΩ±0.02 kΩ load) |
Rise Time (tr) |
≤10 μs |
Time Constant (τ) |
52 μs±5 μs |
Pulse Repetition (t) |
5 ms |
Surge Voltage |
|
Output Voltage Peak |
30 V (+0,-1V) |
Pulse Duration |
300 ms |
Pulse Repetition |
1 min |
Counter |
10 s |
Calibration Resistor |
25 Ω±0.5 Ω, 1 kΩ±0.02 kΩ |
DUT Load(optional) |
30 A, 50 A, 75 A, 100 A |
General Parameters |
|
Working Power Supply |
AC 110V/220V±10%,50/60Hz±5% (AC 220V 50Hz in mainland China by default) |
Ambient Temperature |
5℃ ~ 23℃ |
Relative Humidity |
25% ~ 70% |
Atmospheric Pressure |
86 kPa ~ 106 kPa |
Dimension |
6U |
Weight |
Approx. 50 kg |
Standard Accessories |
Test Line, Power Cord, Fuse (spare parts), Instruction Manual, Calibration Load R25 Ω, Calibration Load R1000 Ω |
Options Accessories |
Autolab Control Software |