Technical Parameters-S20D200 |
|
Test Current |
100 A ~ 2000 A, ±10% |
Charging Voltage |
1 kV ~ 20 kV |
Current Waveform |
Rise time (10% ~ 90%): 10 μs ±20% Duration (50% ~ 50%): 1000 μs ±20% |
Polarity |
Positive/ negative/ alternative |
Source Impedance |
10 Ω |
Repetition (time for single pulse) |
5 s ~ 1000 s (The minimum time is subjected to test voltage) |
Counter |
1~10000 |
Phase Sync. |
0° ~ 360°(45 Hz ~ 65 Hz) |
Pulse Current Monitor |
External, optional |
Trigger Mode |
Manual, Auto, External Trigger |
Dimension |
19” / 35U |
Weight |
Approx. 200 kg |
General Parameters |
|
Display Screen |
5.7” TFT touch screen |
Working Power |
AC 110 V/220 V(±10%), 50 Hz /60 Hz (220 V in mainland China) |
Fuse |
6 A |
Max. Power |
500 W |
Communication Mode |
Ethernet LAN、RJ45 |
External Control Mode |
25-pin parallel port cable |
External Trigger Input |
BNC, 5 V TTL, the node is open, oscilloscope can trigger the product when internal circuit is closed. |
Running Control Input |
BNC, 5 V TTL |
Failure Detection |
The failure information will be displayed on LCD in front panel when failure occurs and interrupt the working of instrument. |
Working Status Indication |
LED indication and LCD display on front panel |
Earthing Mode |
Flat earth line |
Monitor Output Mode |
Standard 1 m coaxial cable |
Ambient Temperature |
15 ℃ ~ 35 ℃ |
Relative Humidity |
45% ~ 75% |
Atmospheric Pressure |
86 kPa ~ 106 kPa |
Accessories |
|
User Manual, Test line, Ground line, 3-core power line, fuses (spare parts), Coaxial cable |
|
Options |
|
Ten-way distribution networks |
SPN 10 |
Coupling/decoupling networks |
CPN 4516S (customized for other load capacity) |
Isolation transformer |
DG-4.4 KVA |
Wide-band Current Monitor |
CM 0220M |
Measurement |
MAS 3000 |
Control Software |
Corelab |