The S6D series is a new type of impulse current simulator developed according to IEC 61643-11, GB/T 18802.11 and IEC 61312-1 standards. Can output 10/1000μs current wave, pulse voltage 6 kV, pulse current up to 1 kA. The device can be paired with a coupled decoupling network and a ten-channel cyclic distribution network SPN-10, so that up to 10 tested devices can simultaneously perform active or passive impulse current test requirements. The product is equipped with the company's measurement and analysis software for professional analysis of waveform data. The operation of the equipment is simple and fast, and the reliability is strong.
Features:
> 5.7 Inch color touch screen;
> Can cooperate with the company's measurement and analysis software to analyze the test waveform;
> It can be equipped with a 10-way circulation distribution network;
> Can be customized according to customer needs;
Naming rule:
Technical Parameters |
|||
Model |
S6D05 |
S6D60 |
S6D100 |
Test Current |
1 A ~ 50 A, ±10% |
10A ~ 600 A, ±10% |
50 A ~ 1000 A, ±10% |
Charging Voltage |
Up to 3.5kV |
Up to 6 kV |
Up to 6 kV |
Current Waveform |
Rise time(10% ~ 90%): 10 μs ± 20% |
||
Duration(50% ~ 50%): 1000 μs ± 20% |
|||
Polarity |
Positive/ Negative/ Alternative |
||
Source Impedance |
50 Ω |
10 Ω |
6 Ω |
Repetition (time for single pulse) |
5 s ~ 99 s (The minimum time is subjected to test voltage) |
5 s ~ 1000s (The minimum time is subjected to test voltage) |
5 s ~1000s (The minimum time is subjected to test voltage) |
Counter |
1~ 10000 |
||
Pulse Current Monitor |
External, optional |
||
Trigger Mode |
Manual, Auto, External Trigger |
||
Dimension |
19 Inch /6U |
19 Inch /22U |
19 Inch /22U |
Weight |
Approx. 50 kg |
Approx. 150 kg |
Approx. 180 kg |
General Parameters |
|||
Display Screen |
5.7 Inch TFT touch screen |
||
Working Power |
AC 220 V(±10%),50 Hz /60 Hz (220 V in mainland China) |
||
Fuse |
6 A |
||
Max. Power |
1000 W |
||
Communication Mode |
Ethernet LAN、RJ45 |
||
External Control Mode |
25-pin parallel port cable |
||
External Trigger Input |
BNC, 5 V TTL, the node is open, oscilloscope can trigger the product when internal circuit is closed. |
||
Running Control Input |
BNC, 5 V TTL |
||
Failure Detection |
The failure information will be displayed on LCD in front panel when failure occurs and interrupt the working of instrument. |
||
Working Status Indication |
LED indication and LCD display on front panel |
||
Earthing Mode |
Flat earth line |
||
Monitor Output Mode |
Standard 1 m coaxial cable |
||
Ambient Temperature |
15 ℃ ~ 35 ℃ |
||
Relative Humidity |
45% ~ 75% |
||
Atmospheric Pressure |
86 kPa ~ 106 kPa |
Optional accessories |
|
Ten-way distribution networks |
SPN-10 |
Coupling/decoupling networks |
CPN 4516S (customized for other load capacity) |
Isolation transformer |
DG-4.4 KVA |
Wide-band Current Monitor |
CM 0220M |
Measurement |
MAS 3000 |
Control Software |
Corelab |
Accessory |
|
User Manual, Test line, Ground line, 3-core power line, fuses (spare parts), Coaxial cable |