EFT 800x series including EFT 800G(source output), EFT 800S (built-in single-phase coupling/decoupling networks) and EFT 800T (built-in three-phase coupling/decoupling networks) are newly designed intelligent EFT/Burst simulators, which comply with IEC 61000-4-4 with test voltage ranging from 200 V to 8000 V and frequency from 100 Hz to 1000 kHz. The maximum EUT load capacity is AC 690 V 32 A, DC 1000 V 32 A.
The generator features with high reliability, stable performance and easy to use.
Features:
> 5.7-inch colorful touch screen;
> Maximum pulse output voltage 8.0 kV;
> Parameter test scheduling test
> Built-in single-phase or three-phase coupling/ decoupling networks, load capacity max. AC 440 V 32 A, DC 1000 V 32 A. Customization is available for specific requirement;
> Ethernet, RJ45 port for PC remote control, print and documentation;
Technical Parameters |
|
Standard |
IEC/EN 61000-4-4, GB/T 17626.4 |
Test Voltage |
200 V ~ 8.0 kV, ± 10% |
Source Output Voltage |
190 V ~ 7600 V±20%,into 1 kΩ load 100 V ~ 4000 V±10%,into 50 Ω load |
CDN Output Voltage |
200 V ~ 4000 V±10%,into 50 Ω load |
Source Impedance |
50 Ω±30% |
Rise time |
Source port: 4 ns ± 30%, into 50 Ω /1000 Ω load CDN port: 4 ns ~ 7 ns, into 50 Ω load |
Pulse Width |
Source port: 50 ns ±30%, into 50 Ω load; 35 ns ~ 150 ns, into 1 kΩ load; CDN port: 30 ns ~ 60 ns, into 50 Ω load |
Polarity |
positive, negative, alternation |
Frequency |
100 Hz ~ 1000 kHz |
Pulse Number in one burst |
≥75 |
Burst Period |
11ms ~ 9999ms |
Test Time |
1 s ~ 9999 s |
CDN |
Built-in /automatic, Residual voltage<10% |
EUT Load Capacity |
MAX AC 690 V 32 A, DC 1000 V 32 A |
General Parameters |
|
Display Screen |
5.7-inch TFT touch screen |
Working Power |
AC 110 V/220 V(±10%), 50 Hz /60 Hz (220 V in mainland China) |
Fuse |
6 A |
Max. Power |
300 W |
Memory Space |
Infinite (PC) |
Communication Mode |
Ethernet LAN、RJ45 |
External Control Mode |
D-25 pin |
CRO Trigger Output |
BNC, 5 V TTL |
External Trigger Input |
BNC, 5 V TTL |
Running Control Input |
BNC, 5 V TTL |
External Sync. Input |
45 Hz ~ 65 Hz, 20 V ~ 500 V for voltage between dotted and undotted terminal. 0 ~ 500 V for voltage between dotted, undotted terminal and chassis. |
Working Status Indication |
LED indication and LCD display on front panel |
Earthing Mode |
Flat earth line |
EUT Power Injection Mode |
4 mm2 banana plug |
Monitor Output Mode |
Standard 1 m coaxial cable |
Dimension |
19 ”/ 4 U |
Weight |
Approx. 25 kg |
Ambient Temperature |
15 ℃ ~ 35 ℃ |
Relative Humidity |
45% ~ 75% |
Atmospheric Pressure |
86 kPa ~ 106 kPa |
Standard Accessories |
|
Three-core power line, Test lines, Ground line, User manual, Coaxial cable, Fuses (spare parts) |
|
Options for External CDN |
|
EFTN 38100T |
|
External three-phase automatic CDN |
Comply with IEC/EN 61000-4-4, test voltage up to 7,0 kV |
EUT load capacity* |
Three-phase-5-line, AC 440 V 100 A, DC 500 V 100 A ,50/60 Hz |
EFTN 69100T |
|
External three-phase automatic CDN |
Comply with IEC/EN 61000-4-4, test voltage up to 7,0 kV |
EUT load capacity* |
Three-phase-5-line, AC 700 V 100 A, DC 1500 V 100 A ,50/60 Hz |
*EUT load capacity can be customized according to specific requirement.
Other Optional Accessories |
|
Capacitive Coupling Clamp CCC 100 |
For tests on lines connected to signal and control port |
EFT/Burst Calibration Kit |
Including attenuator (TFB 500 and TFB 1000), adapter and suitcase. TFB 500:input impedance 50 Ω, output impedance 50 Ω, voltage ratio 500:1; TFB 1000:input impedance 1000 Ω, output impedance 50 Ω, voltage ratio 1000:1; |
Corelab |