- Feature
- Standard
- Parameter
- Fitting
- Services
- Video
The coupling transformer TPT-7637-4C100B is specially designed according to the pulse B test requirement specified in ISO 7637-4:2020, which is capable of transferring time-harmonic signals (sine waves) or pulse signals to EUT through magnetic coupling method with features of distortion-free waveform, and physical isolation from the EUT etc. It is also used in EMC conducted susceptibility / immunity tests of Mazda MES PW 67602, GJB 151A, 151B and MIL-STD-461F.
- MIL-STD-461F
- GJB 151B-2013
- GJB 151A-97
- Mazda MES PW67602
- ISO 7637-4:2020
Technical Parameters
|
Max Unsaturated Voltage
|
15 V@15 Hz≤f≤3 kHz
25 V@3 kHz≤f≤30 kHz
2.5 V@30 kHz≤f≤300 kHz
|
Primary Max Current
|
32 A
|
EUT Max Current
|
100 A
|
Frequency Range
|
10 Hz ~ 300 kHz
|
Dimension
|
440 mm (L)*190 mm (H)*585 mm(D)
|
Weight
|
60 kg
|