IEC/EN 61000-4-6 specifies the design and performance of the Coupled Decoupling Network (CDN) series. Detailed regulations have also been made for the types of cables used and the signals transmitted in each coupled decoupling network.
CDN Mx coupling decoupling network is suitable for power line testing of single-phase 1-wire/2-wire/3-wire, three-phase 4-wire, and three-phase 5-wire. The carrying capacity can be customized according to customer needs.
Features
> Meet the requirements of IEC 61000-4-6:2023;
> Used for unshielded power cords;
> High current coaxial terminal.
Technical Parameters |
|
Standard |
IEC 61000-4-6 |
RF Signal Input Terminal |
BNC |
RF Input Power |
6 W |
Common Mode Impedance (EUT) |
150 kHz ~ 24 MHz:150 Ω±20 Ω 24 MHz ~ 80 MHz: 150 Ω﹢60 Ω/ -45 Ω 80 MHz ~ 230 MHz:150 Ω±60 Ω |
Size |
≤32 A: 210 mm (length) x 115 mm (height) x170 mm (depth) |
Weigh |
Approximately 4.5 kg (based on actual product) |
Selection Guide |
||
Serial Number |
Model |
Technical Parameter |
1 |
CDN M2-100 |
L+N,100 A 700 V AC/1500 V DC(Line-Ground), EUT/AE 25 mm2 , 150 kHz-80 MHz |
2 |
CDN M2M3-16 |
L+N/L+N+PE,16 A 250 V AC/400 V DC(Line-Ground) , EUT/AE 4 mm2 , 150 kHz-230 MHz |
3 |
CDN M2M3 |
L+N/L+N+PE,32 A 250 V AC/400 V DC(Line-Ground), EUT/AE 4 mm2, 150 kHz-230 MHz |
4 |
CDN M3-100 |
L+N+PE,100 A 700 V AC/1500 V DC(Line-Ground),EUT/AE 25 mm2 , 150 kHz-80 MHz |
5 |
CDN M4N-16 |
L1+L2+L3+N,16 A 250 V AC / 400 V DC(Line-Ground),EUT/AE 4 mm2, 150 kHz-230 MHz |
6 |
CDN M4N-32 |
L1+L2+L3+N,32 A 250 V AC / 400 V DC(Line-Ground),EUT/AE 4 mm2 , 150 kHz-230 MHz |
7 |
CDN M4PE-32 |
L1+L2+L3+PE,32A 250 V AC / 400 V DC(Line-Ground),EUT/AE 4 mm2 , 150 kHz-230 MHz |
8 |
CDN M4N-75 |
L1+L2+L3+N,75 A 700 V AC / 1500 V DC(Line-Ground), EUT/AE 25 mm2,150 kHz-80 MHz |
9 |
CDN M5-32 |
L1+L2+L3+N+PE,32 A 250 V AC / 400 V DC(Line-Ground), EUT/AE 4 mm2 , 150 kHz-230 MHz |
10 |
CDN M5-75 |
L1+L2+L3+N+PE,75 A 700 V AC/1500 V DC(Line-Ground),EUT/AE 25 mm2,150 kHz-80 MHz |
11 |
CDN M3L |
L1+L2+L3 ,32 A 250 V AC/400 V DC(Line-Ground), EUT/AE 4mm2 , 150 kHz-230 MHz |
12 |
CDN M3L-75 |
L1+L2+L3 ,75 A 700 V AC / 1500 V DC (Line-Ground), EUT/AE 25 mm2,150 kHz-80 MHz |
13 |
CDN M4N-100 |
L1+L2+L3+N,100 A 700 V AC/1500 V DC(Line-Ground),EUT/AE 25 mm2,150 kHz-80 MHz |
14 |
CDN M5-100 |
L1+L2+L3+N+PE,100 A 700 V AC/1500 V DC(Line-Ground),EUT/AE 25 mm2,150 kHz-80 MHz |
15 |
CDN M4PE-75 |
L1+L2+L3+PE,75 A 700 V AC/1500 V DC(Line-Ground),EUT/AE 25 mm2,150 kHz-80 MHz |
Standard Accessories |
≤32A |
Calibration Adapter, Test Line, Instruction Manual |
>32A |
Calibration Adapter, Fan power Adapter, Test Line, Instruction Manual |
Optional Selection |
Calibration Adapter CDN 100KIT |