Technical Parameters |
|
Standard |
IEC 61000-4-5 |
Generator |
|
Test Voltage(open-circuit waveform) |
0.5 kV ~ 10.0 kV± 10% |
Rise Time |
1.2 μs±30% |
Duration |
50 μs±20% |
Test Current(Short-circuit waveform) |
0.25 kA ~ 5.0 kA± 10% |
Rise Time |
8 μs ± 20% |
Duration |
20 μs ± 20% |
Polarity |
Positive, negative, alternative |
Source Impedance |
2 Ω |
Repetition Rate(single pulse) |
6 s ~ 99 s (The shortest time depends on test voltage) |
Counter |
1~ 999 |
Phase Angle Sync. |
0° ~ 360°(45 Hz ~ 65 Hz) |
Trigger Mode |
Manual, Auto, External Trigger |
CDN |
|
EUT Load Capacity |
AC 250 V, 20 A; DC 220 V, 12 A |
Coupling Capacitance |
9 μF(L-PE), 18μF(L-L) |
Coupling Resistor |
10 Ω(equivalent impedance12 Ω), 0 Ω (equivalent impedance 2 Ω) |
Coupling Attenuation |
<2 dB |
Coupling Switch |
Auto |
Residual surge voltage on EUT injection port |
Not exceed 15% of the maximum applied test voltage or twice the rated peak voltage of the CDN |
General Parameters |
|
Display Screen |
5.7” TFT touch screen |
Working Power |
AC 110 V/220 V(±10%),50 Hz /60 Hz(Default in mainland China:220 V) |
Fuse |
10 A |
Max. Power |
300 W |
Communication Mode |
Ethernet LAN、RJ45 |
External Control Mode |
25-pin parallel port cable |
External Trigger Input |
BNC, 5 V TTL The node is open, oscilloscope can trigger the CWS 800N when internal circuit is closed. |
Running Control Input |
BNC, 5 V TTL |
Failure Detection |
The failure information will be displayed on LCD in front panel when failure occurs and interrupt the working of instrument. |
Working Status Indication |
LED indication and LCD display on front panel |
Earthing Mode |
Flat earth line |
EUT Power Injection Line |
φ4 mm or φ6 mm banana plug |
Dimension |
6U |
Weight |
Approx. 44 kg |
Ambient Temperature |
15 ℃ ~ 35 ℃ |
Relative Humidity |
45% ~ 75% |
Atmospheric Pressure |
86 kPa ~ 106 kPa |
Accessories |
User Manual, Test line, Earth line, 3-core power line, fuses (Spare parts) |
Options |
1. External 3-phase CDN SPN series |
2. Isolation transformer DG-4.4 KVA |
3. Differential Probe VCF-80(Attenuation 1000:1) |
4. Wide-band Current Monitor Clamp CM 0220M |
5. PC control Software CoreLab Support Windows XP and Windows 7; easy operation& beautiful UI; user can easily perform customized testing sequence through each operation function and standard library; generate testing report flexibly. |