Technical Parameters (Signal Generator) |
|
Model No. |
CST 10150DH |
Standard |
ISO 7637-4 Pulse A |
Frequency Range |
1 μHz~100 MHz |
Frequency Resolution |
1 μHz |
Frequency Stability over Temp. |
±1 ppm+10 pHz 18℃~28℃ |
Harmonics |
DC~10MHz (including 10 MHz): <-55dBc 10MHz~20MHz (including 20 MHz): <-50dBc 20MHz~40MHz (including 40 MHz)::<-40dBc >40MHz:<-35dBc |
Non-harmonics |
≤10MHz:<-60dBc >10MHz:<-60dBc+6dB/Octave |
Output Power |
≤10MHz:1.0mVpp~10Vpp ≤30MHz:1.0mVpp~5.0Vpp ≤60MHz:1.0mVpp~2.5Vpp >60MHz:1.0mVpp~1Vpp |
Power Precision |
Typical(1kHz sinusoidal, 0V offset, >10mVpp,automatic) ± (1% of setting value) ±5mV |
Power Meter Resolution |
0.1 mVpp |
Amplitude Modulation(AM) |
Modulation depth: 0%~120%; Modulated rate: 2 mHz ~1 MHz |
Modulated rate: 2 mHz ~1 MHz |
|
Phase modulation :0°~360°; Modulated rate: 2 mHz ~1 MHz |
|
Pulse Repetition |
1 μs ~ 500 s |
Pulse Width |
0 ns~100 s |
Output Interface |
|
Technical Parameters (Power Meter) |
|
Frequency Range |
9 kHz ~ 6 GHz |
Test Electrical Level |
|
Accuracy |
|
Input Interface |
N (female) |
VSWR |
<1.1:1 |
Technical Parameters (Power Amplifier) |
|
Frequency Range |
100 kHz~230 MHz |
Gain |
|
1dB Gain |
51.3 dB±1 dB (135 W) |
VSWR |
<1.5:1 |
Output Impedance |
50 Ω |
Output Interface |
|
General Parameters |
|
Working Power |
AC 110 V/220 V ±10%,50 Hz / 60 Hz±5% (AC 220 V 50 Hz in mainland China) |
Max. Power |
500 W |
Dimension |
19" / 4U |
Weight |
Approx. 15 kg |
Ambient Temperature |
15℃~35℃ |
Relative Humidity |
45%~75% |
Atmospheric Pressure |
86 kPa~106 kPa |
Accessories |
User Manual, Test line, Fuse*2 (spare parts), power line, flat grounded line, attenuator, USB 2.0 printer line, BNC 50 Ω coaxial terminal load, RF cable |
ISO 7637-4 Pulse A Test Setup
Test Environment |
|
Unshielded Room |
Test Table: 2,400 mm *1,000 mm *900 mm |
Ground Reference Plane: 2,400 mm *1,000 mm *1,200 mm |
|
Accessories for ISO 7637-4 Pulse A Test |
|
Attenuator |
30 dB/150 W Frequency Range DC~1 GHz |
Attenuator |
3 dB/200 W Frequency Range DC~1 GHz |
Balanced/ Unbalanced Transformer |
TBT-200: 200 V; 1 MHz ~ 10 MHz; -3.3 dB; 50 Ω; |
HV Artificial Networks |
TANHV 200:100 kHz ~ 150 MHz; 400 A; AC 700 V, DC 1 kV; 5μH || 50 Ω; |
50 Ω Load |
50Ω/200W Frequency Range DC~1 GHz |
HV Shielded Enclosure |
HVSE 400 |
HV Battery Load |
7637-4R500/120 3000 W |
Test Software |
EMC-S 7637-4 |