IEC/EN 61000-4-6 and YY0505 CS Transient Immunity Test Setup
CST 1075 / CST 10150 (CST 1075E/ CST 10150E) |
|
Test Accessories (Voltage Method) |
|
CDN (Coupling / decoupling networks) |
|
Power line (M series) |
M1, M2, M3, M2+M3, M4, M5: Conform to the requirement of single-/three-phase power, Max. current reaches 300 A |
Unscreened balanced lines (T series) |
T2, T4, T8 |
Unscreened balanced lines (AF series) |
AF2, AF4, AF8 |
Screened cables (S series) |
S1, S2, S4, S8, S9, S25 |
Others |
RJ11, RJ11S, RJ45, RJ45S, USB-A, USB-B |
Calibration Jig 150 Ω-to-50 Ω |
CDN 100KIT Quantity:2 sets |
EM Clamp |
|
EM CL100 |
frequency range 100 kHz~1GHz, coupling factor < 3 d (150 kHz ~ 500 MHz), inner diameter 23 mm/32 mm calibration device EM CL100 KIT |
Attenuator |
|
Attenuator |
6 dB/80 W attenuator (CST 1075/ CST 1075E) 6 dB/200 W attenuator (CST 10150/ CST 10150E) |
CST 1075 / CST 10150 (CST 1075E/ CST 10150E) |
|
Test Accessories (Current Method) |
|
Current Injection Probe |
BCIP-400 Frequency range 4 kHz~400 MHz, |
Calibration Device 150 Ω-to-50 Ω |
BCI 100KIT Quantity:2 sets |
Calibration Jig |
BCICF-400 |
ISO 11452-4 BCI Test Setup
CST 1075B / CST 10150B |
|
Accessories for ISO 11452-4 BCI Test |
|
Attenuator |
30 dB/80 W Frequency Range DC~1 GHz |
Attenuator |
3 dB/80 W Frequency Range DC~1 GHz (CST 1075B) |
Attenuator |
3 dB/200 W Frequency Range DC~1 GHz (CST 10150B) |
50 Ω Load |
50 Ω/80 W Frequency Range DC~1 GHz |
Current Injection Probe |
BCIP-400 |
Calibration Device |
BCICF-400 Frequency Range DC~400 MHz |
Current Monitor Probe |
TWCM-500 Frequency Range 1 kHz~500 MHz |
Test Software |
EMC-S BCI |
Test Environment |
|
Conducted in a shielded room |
Test Table: 2,400 mm *1,000 mm *900 mm |
Ground Reference Plane: 2,400 mm *1,000 mm *1,200 mm |
RTCA DO-160 Section 20/ MIL-STD-461 CS114
CS114 Test Setup
CST 1075C / CST 10150C |
|
Accessories for GJB 151B CS 114 Test |
|
Attenuator |
30 dB/80 W Frequency Range DC~1 GHz |
Attenuator |
3 dB/80 W Frequency Range DC~1 GHz (CST 1075C) |
Attenuator |
3 dB/200 W Frequency Range DC~1 GHz (CST 10150C) |
50 Ω Terminal |
50 Ω/80 W Frequency Range DC~1 GHz |
Current Injection Probe |
BCIP-400 |
Calibration Device |
BCICF-400 Frequency Range DC~400 MHz |
Current Monitor Probe |
TWCM-500 Frequency Range 1 KHz~500 MHz |
Test Software |
EMC-S CS114 |
Test Environment |
|
Conducted in a shielded room |
Test Table: 2,400 mm *1,000 mm *900 mm |
Ground Reference Plane: 2,400 mm *1,000 mm *1,200 mm |
ISO 7637-4 Pulse A Test Setup
CST 1075D / CST 10150D |
|
Accessories for ISO 7637-4 Pulse A Test |
|
Attenuator |
30 dB/80 W Frequency Range DC~1 GHz |
Attenuator |
3 dB/80 W Frequency Range DC~1 GHz (CST 1075C) |
Attenuator |
3 dB/200 W Frequency Range DC~1 GHz (CST 10150C) |
Balanced/ Unbalanced Transformer |
TBT-200: 200 V; 1 MHz ~ 10 MHz; -3.3 dB; 50 Ω; |
HV Artificial Networks |
TANHV 200: 100 kHz ~ 150 MHz; 400 A; AC 700 V, DC 1 kV; 5μH || 50 Ω; |
50 Ω Load |
50 Ω/80 W Frequency Range DC~1 GHz |
HV Shielded Enclosure |
HVSE 400 |
HV Shielded Enclosure |
HVSE 200 |
HV Battery Load |
7637-4R500/120 3000 W |
Test Software |
EMC-S 7637-4 |
Test Environment |
|
Conducted in an unshielded room |
Test Table: 2,400 mm *1,000 mm *900 mm |
Ground Reference Plane: 2,400 mm *1,000 mm *1,200 mm |
Accessories |
User Manual, Test line, Fuse*2 (spare parts), power line, flat grounded line, attenuator, USB 2.0 printer line, BNC 50 Ω coaxial terminal load, RF cable |