> 5.7” colorful touch screen operation;
> Meet the test requirement of CS106 in MIL-STD-461F, GJB 151A, GJB 152A and GJB 151B;
> Pulse repetition frequency up to 100 Hz;
> Automatically identify multiple failures;
> Built-in 0.15 μs coupling transformer;
> Max. EUT load current 300 A;
Figure 1:5 μs /10 μs series test connection
Figure 2:0.15 μs series test connection
Figure 3:5 μs /10 μs Parallel test connection
Figure 4:0.15 μs Parallel test
Technical Parameter |
||
Unit type |
TPS-CS106 |
TPS-CS106(1000V) |
Test voltage range |
0 ~ 600 V |
0.15 μs :0 ~ 600 V |
5 μs/10 μs :0 ~ 1000 V |
||
Calibration voltage |
100 V ~ 600 V, ±10% |
0.15 μs :100 V ~ 600 V, ±10% |
5 μs/10 μs :100 V ~ 1000 V, ±10% |
||
GJB 151A-1997 |
0.15 μs pulse (50% ~ 0%) |
≤0.15 μs (<5 ohm) |
5 μs pulse (50% ~ 0%) |
≤5 μs (<2 ohm) |
|
10 μs pulse (50% ~ 0%) |
≤10 μs (<1 ohm) |
|
GJB 151B-2013 |
Rise time |
1.5 μs±0.3 μs |
Fall time |
3.5 μs±0.3 μs |
|
Duration time |
5.0 μs(±10%) |
|
Sag or undershoot amplitude |
≤30% Vp |
|
Sag or undershoot time |
<20 μs |
|
Source impedance |
≤2 Ω |
|
Output Polarity |
+/- (only positive for 0.15 μs) |
|
Trigger |
External, automatic and manual |
|
Pulse repetition frequency |
Standard configuration 1~20 pps |
|
Customizable configuration: |
||
1~50 pps (0.15 μs) |
||
1~100pps (5 μs & 10 μs) |
||
External Phase Sync |
0°~360°, mains frequency 50 Hz~1000 Hz, available for async |
|
Parallel Connection |
Built-in coupler |
|
Series Connection |
5 μs/10 μs coupler external (32 A, 50 A, 100 A, 200 A, 300 A optional, higher current can be customized); 0.15 mu s coupler built-in (32 A, 50 A); |
|
0.15 mu s coupler external (100 A, 200 A, 300 A optional, higher current can be customized) |
||
Output Ports |
4 mm plugs |
|
Calibration Resistance |
External |
|
General parameters |
||
Display Screen |
5.7” TFT touch screen |
|
Power Supply |
AC 220 V 50 Hz |
|
Fuse |
6A |
|
Max. Power Consumption |
200 W |
|
Dimension |
19”/4U |
|
Weight |
Approx.20 kg |
|
Ambient Temperature |
15 ℃~35 ℃ |
|
Relative Humidity |
45% - 75% |
|
Atmospheric Pressure |
86 kPa – 106 kPa |
Standard accessories |
|
User manual, Testing line, Power line, Earth line, Fuses,Calibration resistor CRM 050 |
|
1、Calibration resistance module CRM 050
|
Non-inductive resistance: 5 Ω |
Optional accessories |
|
600V System configuration: |
|
1、Microsecond pulse transformer TPT-600-5
|
For coupling 5 μs, 10 μs waveform, Max Coupling pulse voltage: 600 V |
2、0.15 μs waveform module TPS-CS106-1
|
For coupling 0.15 μs waveform, Max
Coupling pulse voltage: 600 V |
1000V System configuration: |
|
3、Microsecond pulse transformer TPT-1000-1
|
For coupling 5 μs, 10 μs waveform, Max Coupling pulse voltage: 1000 V |
4、0.15 μs waveform module TPS-CS106-100
|
For coupling 0.15 μs waveform, Max
Coupling pulse voltage: 600 V |
5、Microsecond pulse transformer TPT-600-4
|
For coupling 5 μs, 10 μs waveform, |
6、Feed-through capacitor DCM 4032
|
Voltage:500 V AC |
7、 Feed-through capacitor DCM 4050
|
Voltage:500 V AC |
8、Feed-through capacitor DCM 40100
|
Voltage:500 V AC |
9、Artificial mains network LISN J50
|
Inductance:50 μH; |