YD
Features:
LCD display, built-in computer program, easy to operate;
High-power resistor, stable output current;
Selectable current-limit resistor;
Adjustable current injection time;
Built-in two test mode: power induction and contact test;
Built-in CDN, bi-port to output;
RS 232 communication interface, remote control, and restore data automatically.
Technical Data |
|
Voltage range |
0.2-1.5kV |
Injection time |
0.1s-30min |
Test times |
1-999 |
Interval |
1-99s |
Test mode |
power induction and contact test |
Power induction impedance |
200Ω/600Ω, output>10A2S |
Contact test impedance |
10Ω±10%, 20Ω±10%, 40Ω±10%, 80Ω±10%, 160Ω±10%, 300Ω±10%, 600Ω±10%, 1000Ω±10% |
Trigger mode |
Automatic/ manual |
Network capacity |
single-phase three-line, AC 220V16A |
Operating mains |
single-phase AC 220V±10%, 50/60Hz |