General Description
PFS 2216 simulates voltage dip, interruption and variation which are caused by power grid and transformer devices due to malfunction or sudden large change of load. It is required to test this kind of phenomena to check whether electronic and electrical device can sustain safety operating condition. PFS 2216 can conduct full compliant test as per IEC 61000-4-11.
As Per:
IEC/EN 61000-4-11
IEC/EN 61000-4-29
GB/T 17626.11
GB/T 17626.29
Features:
5.7 inch color touch screen
Full compliant test as per IEC 61000-4-11
Built-in multifunctional test module
Data acquisition of voltage and current
Programmable test procedures
Ethernet RJ45, PC remote control, test report documentation and print
General Data |
||||
Display |
5.7inch TFT color touch screen |
|||
Power supply |
110V/220V, ±10%, 50/60Hz |
|||
Fuse |
6A |
|||
Max. power consumption |
200W |
|||
Memory space |
Infinite |
|||
Communication mode |
Ethernet ,RJ45 |
|||
Auxiliary interface |
D-sub 25p |
|||
External trigger input |
BNC, 5V TTL |
|||
CRO output |
BNC, 5V TTL |
|||
Input |
BNC, 5V TTL |
|||
Synchronization |
45-65Hz,20-500V between dotted terminal &undotted terminal |
|||
0-500V among dotted terminal, undotted terminal& case |
||||
Warning LED |
0-220V AC10A/0-48V DC3A |
|||
Power depends on external signal lamp |
||||
Safety circuit |
The test only can be started when it is closed |
|||
Failure test |
Display on LCD and interrupt the work at failure case |
|||
Voltage monitor output |
BNC, 100:1 coaxial output |
|||
Current monitor output |
BNC,5A:1V coaxial output |
|||
Working indicator |
LED,LCD display |
|||
Grounding connection |
Flat grounding line |
|||
EUT power injection |
4mm² banana line |
|||
Output mode |
1m coaxial cable |
|||
Size |
19 inch/6 U |
|||
Weight |
40kg |
|||
Temperature |
15-35℃ |
|||
Humidity |
45% - 75% |
|||
Air pressure |
86kpa- 106kpa |
|||
Power fail simulator as per IEC 61000-4-11and IEC 61000-4-29 |
||||
Power fail simulator |
||||
Standards |
IEC/EN 61000-4-11,GB/T 17626.11, IEC/EN 61000-4-29, GB/T 17626.29 |
|||
EUT Max voltage |
250V AC, 250V DC |
|||
EUT max current |
16A AC/DC continuous current |
|||
23A last 5s,40Alast 3s,500Aimpulse current |
||||
Max input mains |
220V±5%,50/60Hz±5% |
DC 300V |
||
EUT current and voltage measurement |
LCD display |
|||
BNC terminal: voltage 100:1 current10A:1V |
||||
Interrupt level |
0% |
|||
Dip level |
0% - 100%( for accessories VVT/VMT) |
|||
0%, 40%,70%,80%(for accessories VVT*****SF series) |
||||
Repetition rate |
0.3-9999 cycle or 5ms-9999ms |
|||
Duration |
5ms – 9999ms |
|||
Test time |
1s – 9999s |
|||
Rise and fall time |
1 – 5us(100Ω load) |
|||
Voltage variation level |
0 – 100% |
|||
Time for decreasing voltage |
500ms – 9999ms (50%-100%) or 1-5us(100Ω load) |
|||
1000ms – 9999ms (0%- 100%) or 1-5us(100Ω load) |
||||
Time for increasing voltage |
500ms – 9999ms (50% - 100%) |
|||
1000ms – 9999ms (0% - 100%) |
||||
Time for reduced voltage |
10ms – 99999ms |
|||
Synchronization |
0-360°, resolution 1° |
|||
Trigger |
Auto, manual, external |
|||
Optional function |
Additional module for voltage variation test |
|||
Description of internal CDN |
||||
Model |
Features |
Remarks |
||
PFS 2216 |
AC 250V single phase,16A |
DC 250V/16A |
||
EUT fuse PFS 2216 has built-in power fuse. 20A fuse for PF1; 40A fuse for PF2 |