CDN-405 T8 is the coupling/decoupling network to couple surge pulses to unshielded symmetrical high-speed communication line in the test. Data rate is up to 10/100/1,000MBit/s. The powerful decoupling capacity makes the auxiliary equipment immunity to surge pulses, and makes sure the test repetition. There is only 90V residual voltage on the AE port with 2kV test voltage, no additional decoupling device needed. CDN-405 T8 is designed to meet the requirements of IEC/EN 61000-4-5figure 14. Stable decoupling capacity and data transfer rate, easy to carry and use.
As Per:
IEC 61000-4-5
EN 61000-4-5
GB/T 17626.5
ITU-TK.20
ITU-TK.21
ITU-TK.45
Features:
Data rate up to 10/100/1,000MBit/s
Coupling to 1 pair, 2 pairs or 4 pairs communication line
Surge voltage up to 6kV
Changeable current-limiting module to meet different requirements of standards
Compatible to all kinds of simulators
No extra protection of auxiliary equipments
Technical Data |
||
Model |
CDN-405 T8 |
|
Standards |
IEC/EN 61000-4-5(figure12) |
|
Coupling waveform output impedance |
1.2/50us, 8/20us |
|
optional SZR 160(160Ω±5%) |
||
Coupling waveform output impedance |
10/700us, 5/320us |
|
standard SZR 200(200Ω±5%) |
||
Pulse voltage |
6kV |
|
Coupling mode |
4 pair unshielded symmetrical line |
|
Coupling device |
built-in SCD 90 (90V gas arrestor) |
|
Connection |
RJ 45 female connector |
|
Terminal layout |
Pair 1: pins 1/2 |
|
Pair 2: pins 3/6 |
||
Pair 3: pins 4/5 |
||
Pair 4: pins 7/8 |
||
Data rate |
up to 1,000MBit/s |
|
Operating current |
Max.1A |
|
Decoupling inductance |
20mH |
|
Residual voltage |
90V |
|
General Data |
||
Weight |
4.5kg |
|
Dimension |
LxWxH: 350x200x133cm |
|
Material |
aluminum |
|
Temperature |
5℃-40℃ |
|
Humidity |
20%-80% |
|
Package |
carton |
|
Optional Accessories |
||
SZR 100 |
100ohm |
|
SZR 160 |
160ohm |
|
SZR 200 |
200ohm |
|
SZR 160 |
160ohm |
|
SZR 100 |
100nF coupling module(capacitance) |
|
SCD 90 |
90V coupling module (gas arrestor) |
Accessories |
||
HV cable |
1m, banana plug |
1 |
Ground cable |
0.5m yellow green cable |
1 |
Short earth wire |
black |
1 |
SZR 200 |
current-limiting module |
8 |
Documents |
factory test report |
1 |
user manual |
1 |