Ergonomic design
LCD touch screen
All-in-one design (no base unit)
Changeable R/C networks
Automatic polarity switching
Battery or mains operation, long battery life
Temperature and humidity monitoring
As per:
IEC/EN 61000-6-1
IEC/EN 61000-6-2
IEC/EN 61000-4-2
IEC/EN 61340-3-1
IEC/EN 61326
ISO 10605
ITU-T K.20
GB/T 17626.2
Technical Data |
|
Contact discharge |
1,000V-18,000V +/-5% |
Air discharge |
1,000V-18,000V +/-5% |
Voltage step |
100V |
Hold time |
>5s |
Polarity |
Positive, negative, alternative |
RC module |
LCD display |
Humidity &Temperature |
Internal hygrothermograph, record and protect |
Repetition frequency |
Single/0.1/0.2/0.5/1/2/5/10/20 Hz |
Trigger mode |
Manual/automatic |
Pulse |
1-9999 |
Manual control |
via touch screen |
Remote control |
via fiber optical connector by PC |
Power Supply |
|
Battery powered |
18kV contact discharge, 1HZ, discharge 20H |
Automatically switch off after no operation for more than 10min. |
|
Standby time more than 30h |
|
Battery type |
NIMH |
Charger |
Powered via MAD adapter |
Adaptor |
Replace the battery in continuous test |
Output |
|
Contact discharge |
as per IEC/EN 61000-4-2 |
150pF/330Ω |
|
First peak current |
7.5A ±10% @2kV |
15.0A ±10% @4kV |
|
22.5A ±10% @6kV |
|
30.0A ±10% @8kV |
|
Current value at 30ns |
4.0A ±30% @2kV |
8.0A ±30% @4kV |
|
12.0A ±30% @6kV |
|
16.0A ±30% @8kV |
|
Current value at 60ns |
2.0A ±30% @2kV |
4.0A ±30% @4kV |
|
6.0A ±30% @6kV |
|
8.0A ±30% @8kV |
|
Test program |
|
Summary procedure |
Test according to different standards |
Quick start |
Simple and easy to reset data on line |
Evaluation procedure |
Contact discharge test at 20Hz |
Evaluate the test points of DUT |
|
Standards |
Comply with EN/IEC 61000-4-2and EN 61000-6-1/-6-2 |
Setup |
Parameters and standards level |
General Data |
|
Weight |
1700 gram (battery included) |
Material |
ABS plastic |
Temperature |
5℃ -40℃ |
Humidity |
20 – 80% |
Mains |
100V-240V +/-10%, 50/60Hz |
Basic equipment |
|
R/C module |
150pF/330 ohm discharging module, renewable |
Discharging pole |
Air discharging tip, contact discharging tip |
Adapter |
Replace the battery in continuous test |
Grounding line |
2m |
Package |
suitcase |
Documents |
Manual and test report |
Accessories |
|
DM1-RFC1 |
150pF/330 ohm |
Fast relay discharge module |
|
Rise time 200ps-300ps |
|
DM2 |
150pF/2,000 ohm(ISO 10605) |
|
|
|
|
DM5 |
330pF/2,000 ohm(ISO 10605) |
DM6 |
330pF/330 ohm(ISO 10605) |
DM7 |
100pF/1,500 ohm |
DM8 |
150pF/150 ohm |
DM9 |
500pF/500 ohm |
DM10 |
500pF/5000 ohm |
DMX |
Customized discharge module |
Esd.control |
Software for remote-control and report generation |
Fiber optic interface |
|
Grounding HV resistance |
2×470 kohm |
Vertical coupling plane |
50×50cm |
Horizontal coupling plane |
1600×80cm |
Reference ground |
2700×1800cm |
Test table |
1.6×0.8m, solid wood |
Comply with IEC 61000-4-2 |
|
Fiber optic interface |
USB |
The cable of3mor6m |
|
Max. baud rate: 19,200 |
|
ESD Calibration set |
To calibrate the waveform of IEC/EN61000-4-2, including 2 ohm target, 4GHz attenuator, coaxial cable and use manual. |